Hydrocephalus Phase not stated Binary Endpoint NCT04285489

A Study on the Safety of Hakim Programmable Shunt System: Complete Statistical Analysis

This analysis examines a completed, multicenter retrospective registry study of the Hakim Programmable Shunt System for hydrocephalus. The registry record describes a one-year safety endpoint, but does not report its outcome count or a statistical analysis.

Trial start: 2020-05-02  ·  Enrollment: 130  ·  Sponsor: Integra LifeSciences Corporation
Scope of this record

This page provides an independent statistical analysis and educational interpretation of publicly reported results. ClinicalTrials.gov provides the official trial registry record. Numerical trial results on this page are restricted to the results posted in the ClinicalTrials.gov record; calculations added by Clinical Biostats are labelled as such.

1. Trial at a Glance

This page covers the registry results for A Study on the Safety of Hakim Programmable Shunt System (NCT04285489), a registered phase not stated study. The primary outcome is Number of Participants With Non-infection Within One Year.

130
Enrollment
Phase not stated
n/a
Arms
In the primary outcome
n/a
Effect
No re-analysis shown
n/a
95% CI
See limitations
FeatureRegistry value
ClinicalTrials.gov identifierNCT04285489
PhasePhase not stated
ConditionHydrocephalus
AllocationNot Stated
Design modelNot Stated
MaskingNot Stated
Enrollment130
Arms in the primary outcomen/a
Lead sponsorIntegra LifeSciences Corporation
Results postedYes

2. Clinical Question

Population

The registry describes 130 participants implanted with a Hakim shunting system for hydrocephalus and identifies the primary endpoint population as participants implanted for one year. The record does not give further eligibility criteria or describe how participants were selected.

Intervention

The device is the Hakim Shunt Programmable System, also named the HAKIM Programmable Shunt System in the adverse-event group. The study aimed to collect safety information after implantation. The brief summary says device safety would be assessed using adverse events within one year after catheter implantation.

Comparator

No comparator group is listed. The registry record does not state an allocation method, and this is not a randomized comparison. The adverse-event results are listed for one device arm, so they cannot be read as a like-for-like comparison with another treatment or device.

Primary question

The primary outcome is titled “Number of Participants With Non-infection Within One Year” and is described as a non-infection rate within one year. The record does not report the number of participants meeting this endpoint or a statistical analysis of it. The wording does not clarify exactly how “non-infection” was operationally defined.

3. Trial Design

This is a multicenter, retrospective registry study listed as completed. Its official title describes a safety study of the Hakim Programmable Shunt System, and its brief summary says it aimed to collect safety information from subjects implanted with the device. The registry lists hydrocephalus as the condition and 130 as the enrollment.

The study began on 2020-05-02 and had a primary completion date of 2020-07-28. The endpoint timeframe is one year. The brief summary describes assessment of adverse events occurring within one year after catheter implantation. The record does not explain how retrospective follow-up was conducted, whether the full timeframe was available for every participant, or how events were identified and verified.

The registry lists a single HAKIM Programmable Shunt System Arm for adverse-event reporting. No control arm or comparator is reported, and allocation is not stated. As a result, the design supports a descriptive reading of the recorded safety information, not a randomized treatment comparison. The registry entries do not establish whether other care or patient characteristics influenced the recorded events.

The sponsor is Integra LifeSciences Corporation. The brief summary names Codman & Shurtleff, Inc. of the United States as the producer of the device. These details identify the registry record and device; they do not establish the completeness or independence of event ascertainment. The registry record does not report a protocol, eligibility criteria, recruitment method, or details of the participating centers.

Although the record is marked completed, that status does not itself indicate that every planned outcome was reported. In particular, the primary endpoint is described, but its observed result is not reported in the registry record. The record lists no statistical analyses.

4. Participant Flow and Accounting

The registry reports how participants moved through each stage of the study. All counts below are exactly as posted; missing counts are not inferred from other stages.

Before assignment: Screened 140 patients, 130 of them were enrolled, including 71 adult patients and 59 minors (subject age below 18). 10 patients were screening failures for inclusion/exclusion criteria deviation.

Overall Study

StageHAKIM Programmable Shunt System Arm
STARTED130
COMPLETED130
NOT COMPLETED0

Analysis population for the primary outcome, as defined in the registry: 130 participants implanted Hakim shunting system for 1 year

5. Baseline Characteristics

The table reproduces the baseline characteristics posted in the registry, which describe the participants analysed at baseline and help show whether the randomized groups were comparable.

Population: 130 enrolled subjects were included into PPS.

CharacteristicUnitHAKIM Programmable Shunt System Arm
Participants analysed130
Age, Categorical: <=18 yearsParticipants59
Age, Categorical: Between 18 and 65 yearsParticipants71
Age, Categorical: >=65 yearsParticipants0
Age, Continuousyears30.03 (SD 24.48)
Sex: Female, Male: FemaleParticipants54
Sex: Female, Male: MaleParticipants76
Race (NIH/OMB): American Indian or Alaska NativeParticipants0
Race (NIH/OMB): AsianParticipants130
Race (NIH/OMB): Native Hawaiian or Other Pacific IslanderParticipants0
Race (NIH/OMB): Black or African AmericanParticipants0
Race (NIH/OMB): WhiteParticipants0
Race (NIH/OMB): More than one raceParticipants0
Race (NIH/OMB): Unknown or Not ReportedParticipants0
Region of Enrollment: Chinaparticipants130

6. Primary Endpoint

The registry lists the primary outcome as Number of Participants With Non-infection Within One Year, measured over 1 year.

ElementRegistry entry
Result typeCount Of Participants
Measure of spreadnot applicable
UnitParticipants
Endpoint classificationBinary Endpoint

The primary endpoint is titled “Number of Participants With Non-infection Within One Year.” Its unit is participants, its measure is a count of participants, and its timeframe is one year. The description calls it a “non-infection rate of a subject within one year,” while the title refers to a number of participants. This wording leaves the precise event definition unclear: the registry record does not explain which events qualify as non-infection or how the endpoint was classified.

A participant count is different from a count of all events. If a participant can experience more than one event, a count of participants with at least one qualifying event treats that participant differently from an event total. The endpoint title indicates a participant-based measure, but the registry record does not provide further operational detail to confirm how repeat events were handled.

A one-year safety endpoint provides a defined period in which events are considered, making the timeframe part of the outcome’s meaning. It does not, by itself, show whether follow-up was complete for all participants or whether the endpoint was assessed consistently. Those details are not reported in the registry record.

The endpoint may be used to describe the recorded occurrence of the specified safety outcome after implantation. However, its observed count and rate are not reported in the registry record. Without the endpoint result and a clear definition, no estimate of its frequency or precision can be stated from this record.

7. Why No Re-analysis Is Shown

Reported as posted, not recalculated. Not a randomized comparison (allocation: not stated); arms are not a like-for-like control comparison. A result is recalculated only when the posted data support a clean two-arm comparison, so no result is shown beyond what the sponsor posted.

8. Statistical Interpretation

Clinical Biostats interpretation

The registry describes a completed, retrospective safety study with enrollment of 130 and a one-year primary timeframe. Its primary endpoint concerns participants with “non-infection,” but the record does not report the endpoint count or a statistical analysis. Consequently, the endpoint’s observed frequency and precision cannot be assessed from the information reported in the registry record.

The adverse-event information is separate from that missing primary result. In the single HAKIM Programmable Shunt System Arm, the record lists 31 participants at risk and affected for serious adverse events, and 9 at risk and affected for other adverse events, each with 130 at risk. It also lists 4 deaths. These are descriptive registry figures, not comparative estimates. The record does not state whether the serious-event and other-event categories overlap, how deaths relate to those categories, or whether all events occurred within the primary endpoint timeframe.

The listed serious adverse-event terms include Neurological disorders at 5.4%, Product problems at 4.6%, Intracranial infection at 4.6%, Injuries at 4.6%, Pneumonia at 1.5%, and tumor at 1.5%. The registry does not explain whether terms are mutually exclusive, whether the percentages refer to participants or events, or how terms were selected for listing. They should therefore be read as reported term-level figures, not as a complete event distribution.

Because no comparator is reported, the recorded counts cannot establish whether the device caused an event or whether event occurrence differed from another device or treatment. A single-arm safety registry can describe what was recorded among the listed participants, but it cannot separate device-related effects from other possible explanations without additional design and analysis information.

The record lists zero analyses. No confidence intervals, hypothesis tests, adjusted estimates, or other statistical analysis results are reported. A point count alone does not show how precisely an underlying event frequency has been estimated. General statistical interpretation would normally consider the uncertainty around an estimate as well as the quality and completeness of event capture; those features cannot be evaluated from the available registry entries.

The completed status is a registry status, not evidence that all outcomes are fully reported. In particular, the primary endpoint result is absent. The reported adverse-event information can be described as recorded, but it should not be treated as a complete account of safety or as evidence for a causal conclusion.

9. Statistical Methods Explained

The statistical information in the registry is limited. It identifies a participant-count primary outcome and records adverse-event counts and term percentages, but lists no analyses. No statistical plan, analysis population definition, or confidence interval is reported in the registry record. The interpretation should therefore stay descriptive and should not imply that an unreported statistical test or model was used.

What does a participant count represent?

A binary outcome classifies each participant according to whether a defined event or condition was recorded during a specified period. A count of participants meeting that definition is not the same as a count of all events: one participant may have more than one event, while a participant-based outcome ordinarily counts that person according to whether the criterion was met. The primary endpoint title uses a participant count, but its definition is not detailed enough to determine precisely how events were classified or repeated events treated.

To interpret a participant count as a rate or proportion, a reader needs a clearly defined numerator and denominator that refer to the same analysis population and follow-up period. Here, the endpoint description identifies a population of 130 participants implanted with the system for one year, but does not report the number meeting the endpoint. The denominator details, handling of incomplete follow-up, and endpoint result are not reported in the registry record. No endpoint rate can therefore be stated.

Why does the event definition matter?

Consistent definitions help ensure that events are classified similarly across participants and centers. The primary outcome’s use of “non-infection” is not explained beyond its title and short description. The record does not specify which events count, how infections are distinguished from non-infections, or whether the outcome refers to any non-infection event or another classification. Such ambiguity limits interpretation even before considering statistical uncertainty.

General statistical practice would report an estimate alongside a confidence interval when appropriate. A confidence interval describes the uncertainty associated with an estimate under the assumptions of the method; it does not account automatically for missing events, misclassification, or selection bias. No interval for the primary endpoint or adverse-event counts is reported in the registry record, so their statistical precision cannot be quantified.

Can the adverse-event counts be compared?

The record reports one device arm rather than a comparator group. Counts for serious and other adverse events can describe what was recorded in that arm, but they do not estimate a contrast between treatments. A treatment comparison requires suitable groups and an analysis designed to account for how those groups were formed. No such comparison is reported, and the record states that allocation is not stated and that this is not a randomized comparison.

Even within one arm, event categories need careful interpretation. The registry does not say whether a participant could appear in both the serious and other adverse-event counts, whether a death was also counted among those affected, or whether the term percentages refer to participants or events. General statistical practice distinguishes participants experiencing events from total event episodes, because these answer different questions. The record does not provide enough detail to reconcile those quantities.

What can a planning illustration establish?

The record describes a planning illustration based on an observed effect, with a two-sided significance level of 0.05, equal allocation between two arms, and a normal approximation. It says that the effect to detect is a stated fraction of the observed effect, and distinguishes total events for time-to-event illustrations from participants per arm for other illustrations. These are planning conventions, not evidence that the trial used those assumptions in its design. The registry record does not report a sample-size justification or a statistical plan for the study itself. A planning illustration is not observed power and does not supply a missing endpoint result.

In general, power calculations depend on assumptions about the effect, variability, allocation, outcome type, and analysis. If the assumptions differ from the study context, the resulting planning values may not describe what the study could detect. Since no comparator or primary endpoint analysis is reported, the planning conventions should not be used to infer a treatment effect or the certainty of a safety conclusion.

Why might event variability affect analysis?

For event counts, general methods may need to account for variation greater than a simple model expects, sometimes called over-dispersion. It can arise when event counts vary more across participants than the model allows, and can make standard errors and confidence intervals too optimistic if ignored. This is a general consideration, not a claim about the data in this registry. The record does not report a count model or information sufficient to assess over-dispersion.

For a binary participant outcome, the analysis should also align the statistical method with the outcome definition, follow-up, and denominator. The registry’s zero listed analyses means no test, model, or adjustment can be attributed to the posted results. Descriptive counts should not be presented as if they were adjusted estimates or formal evidence of a difference.

10. Exact Estimates for Each Arm

No two-arm comparison is shown for this trial, but each arm's result can still be summarized with exact interval estimates computed from the posted counts. The Clopper-Pearson interval is exact and conservative; the Wilson interval is a common closer-to-nominal alternative; the Bayesian credible interval uses a uniform Beta(1, 1) prior. For small groups the three can differ noticeably.

ArmParticipantsEventsObserved %Clopper-Pearson 95% CIWilson 95% CIBayesian 95% credible interval
Treatment Arm, Single Arm Study13053.8%1.3% to 8.7%1.7% to 8.7%1.7% to 8.7%

R code and output

arm    <- c("Treatment Arm, Single Arm Study")
n      <- c(130)
events <- c(5)
for (i in seq_along(n)) {
  ci <- binom.test(events[i], n[i])$conf.int          # Clopper-Pearson exact interval
  cr <- qbeta(c(0.025, 0.975), 1 + events[i], 1 + n[i] - events[i])   # Bayesian, uniform Beta(1,1) prior
  wi <- (function(x, n) { p <- x / n; z <- qnorm(0.975); d <- 1 + z^2 / n
    c((p + z^2 / (2 * n) - z * sqrt(p * (1 - p) / n + z^2 / (4 * n^2))) / d, (p + z^2 / (2 * n) + z * sqrt(p * (1 - p) / n + z^2 / (4 * n^2))) / d) })(events[i], n[i])
  cat(sprintf("ARM|%s|%d|%d|%.1f|%.1f|%.1f|%.1f|%.1f|%.1f|%.1f\n", arm[i], n[i], events[i], 100 * events[i] / n[i],
              100 * ci[1], 100 * ci[2], 100 * wi[1], 100 * wi[2], 100 * cr[1], 100 * cr[2]))
}
ARM  Treatment Arm, Single Arm Study  130  5  3.8  1.3  8.7  1.7  8.7  1.7  8.7

11. Multiplicity, Missing Data and Analysis Populations

The registry record lists one primary outcome measure and zero analyses. It does not report a statistical plan, a hierarchy of outcomes, or a plan for handling multiple comparisons. Multiplicity arises when several hypotheses or outcomes are tested, because repeated testing can increase the chance of a result appearing statistically notable by chance. This is a general statistical concern; the record does not show that formal hypothesis testing was conducted or that a multiplicity adjustment was needed or used.

The primary endpoint result itself is not reported in the registry record. The record does not describe whether other outcomes were planned, how outcomes were selected for reporting, or whether any analyses were prespecified. It is therefore not possible to assess selective reporting or to identify an analysis set from the registry information alone.

Missing-data handling is not reported in the registry record. The one-year timeframe is specified, but the record does not say how participants without complete follow-up were handled, whether outcome status was available for everyone, or how missing event information was classified. Missingness can affect an estimate if the availability of data is related to participant characteristics or event status. No assumption about the pattern or impact of missing data can be made.

The analysis populations are also not reported in the registry record. Enrollment is listed as 130, and the primary population description also refers to 130 participants implanted with the shunting system for one year. The record does not explain whether those descriptions correspond to the same analysis set, define exclusions, or indicate how follow-up availability affected inclusion in an analysis.

These gaps do not establish that the study had missing data, selective reporting, or multiplicity problems. They mean that the registry record does not contain the information needed to evaluate those issues. The reported event figures should be understood as registry descriptions, not as results from a documented inferential analysis.

12. Safety Results

The registry reports serious adverse events as affected participants divided by participants at risk.

ArmParticipants with serious adverse eventsParticipants at riskPercentage
HAKIM Programmable Shunt System Arm3113023.8%

Deaths

ArmDeaths (participants affected of at risk)
HAKIM Programmable Shunt System Arm4 of 130

Other (non-serious) adverse events

Participants with at least one non-serious event at or above the registry's 5% reporting threshold.

ArmParticipants affected of at risk
HAKIM Programmable Shunt System Arm9 of 130

Most frequent serious adverse event terms

Event termOrgan systemHAKIM Programmable Shunt System Arm
Neurological disordersNervous system disorders7 of 130
Product problemsProduct Issues6 of 130
Intracranial infectionRespiratory, thoracic and mediastinal disorders6 of 130
InjuriesInjury, poisoning and procedural complications6 of 130
PneumoniaRespiratory, thoracic and mediastinal disorders2 of 130
tumorNeoplasms benign, malignant and unspecified (incl cysts and polyps)2 of 130
Upper respiratory tract infectionRespiratory, thoracic and mediastinal disorders1 of 130
CraniosynostosisCongenital, familial and genetic disorders1 of 130

Most frequent non-serious adverse event terms

Event termOrgan systemHAKIM Programmable Shunt System Arm
Product problemsProduct Issues9 of 130
PneumoniaInfections and infestations9 of 130
HyponatremiaMetabolism and nutrition disorders7 of 130

Serious events with the highest arm-level rate: neurological disorders (5.4%), product problems (4.6%), intracranial infection (4.6%), injuries (4.6%), pneumonia (1.5%).

Do not overextend the safety comparison. Serious-adverse-event counts are safety observations, not efficacy outcomes, and should not be combined with the primary result into a single benefit-risk number.

The adverse-event group is the HAKIM Programmable Shunt System Arm. The registry lists 130 participants at risk for serious adverse events and 31 affected; for other adverse events it lists 130 at risk and 9 affected. It also lists 4 deaths. These figures describe what the registry reports, but do not by themselves establish event causation or comparative risk.

The listed serious-event terms and percentages are Neurological disorders at 5.4%, Product problems at 4.6%, Intracranial infection at 4.6%, Injuries at 4.6%, Pneumonia at 1.5%, and tumor at 1.5%. The record does not explain whether these terms can overlap, whether percentages are based on participants or event episodes, or how the terms were selected. They should not be added or treated as a mutually exclusive breakdown.

The record does not state whether deaths overlap with serious or other adverse events, nor does it clarify whether these figures all use the one-year timeframe. The primary endpoint is described separately and its result is not reported. Accordingly, adverse-event listings should be read as descriptive safety information with important denominator, timing, and classification details left unspecified.

13. What the Result Does, and Does Not, Mean

The posted registry information supports a narrow conclusion: it records a completed, multicenter, retrospective safety study of the Hakim Programmable Shunt System, with enrollment of 130, a one-year primary timeframe, and adverse-event figures for one device arm. It lists 31 participants affected by serious adverse events, 9 affected by other adverse events, and 4 deaths. These figures are descriptive; they are not estimates of a difference between the device and another treatment.

The primary endpoint is a count of participants with “non-infection” within one year, but the result is not reported in the registry record. Its wording is also insufficiently detailed to establish exactly what qualifies. Thus, the central endpoint cannot be used to quantify the recorded frequency of the outcome from this record.

The figures do not establish that the device caused any listed event, nor do they establish that the device prevented or increased events. A retrospective registry without a reported comparator cannot rule out other explanations for an event, including the underlying condition, other care, or differences in participant characteristics. The record does not provide the detail needed to assess those possibilities.

The listing of adverse events also does not establish that every event was captured or that every participant had complete follow-up for the stated timeframe. Completeness of follow-up and event ascertainment methods are not reported in the registry record. Nor does the completed study status resolve those questions.

General statistical interpretation distinguishes the observed information in a registry from a causal treatment effect. A causal claim typically requires a design and analysis that address how treatment was received and how groups may differ. No randomized comparison or comparator arm is reported. The record also lists no analyses, confidence intervals, or adjusted estimates. Therefore, it does not show the precision of an estimated event frequency or support a formal comparison.

The appropriate reading is limited to the outcomes and counts actually recorded, with their definitions and context kept in view. The record does not establish a complete safety profile, quantify the primary endpoint, or determine whether the device changed risk relative to an alternative.

14. Why This Trial Matters Statistically

This study matters statistically because safety registries often collect outcomes that are difficult to interpret without precise definitions, follow-up information, and clear denominators. The record identifies a one-year primary endpoint and reports adverse-event information, but the primary result is absent. That gap illustrates why an outcome’s title alone is not enough to evaluate its frequency or precision.

The distinction between participants affected and event episodes is important in safety reporting. A participant-based count answers how many people met a definition; an event count answers how many episodes were recorded. The registry’s primary outcome is explicitly participant-based, while the adverse-event details do not clarify all counting conventions. Keeping those measures separate avoids treating them as interchangeable.

The study also illustrates the limits of single-arm evidence. A registry can document events among participants who received a device, but without a comparator it cannot estimate a relative difference or separate the device’s contribution from other causes. The retrospective design and unspecified allocation further mean that a randomized contrast is not available in the reported record.

Finally, statistical precision and data quality are distinct considerations. Confidence intervals can describe sampling uncertainty in an estimate, but they cannot repair unclear event definitions, incomplete follow-up, or unreported ascertainment procedures. Here, no statistical analyses or intervals are listed, and the record does not explain those data-collection details. Readers can describe the counts and listed terms, while recognizing that the information does not support a complete inferential safety assessment.

15. Limitations

Several limitations are specific to the information recorded for this study. First, the primary endpoint result is not reported in the registry record. Its title refers to participants with “non-infection,” while its description calls it a non-infection rate; the record does not define the classification or explain how the endpoint was determined. This prevents a clear interpretation of what the measure was intended to capture.

Second, the design is retrospective and no comparator is listed. Allocation is not stated, and the record identifies no like-for-like control comparison. The adverse-event counts therefore describe one device arm and cannot establish a comparative effect or causal relationship.

Third, follow-up and event ascertainment details are not reported. Although the primary timeframe is one year and the brief summary refers to events within one year after catheter implantation, the record does not explain completeness of follow-up, methods for identifying events, or handling of participants whose status was unavailable. It also does not say whether the adverse-event figures all use the same timeframe as the primary endpoint.

Fourth, event-counting conventions are unclear. The record does not state whether serious and other adverse-event categories overlap, how deaths relate to those categories, or whether the listed term percentages refer to participants or events. The percentages should not be read as a mutually exclusive distribution.

Finally, no analyses are listed. Statistical methods, analysis populations, missing-data handling, and any sample-size justification are not reported in the registry record. These limitations describe gaps in the available record; they do not prove that the underlying study lacked procedures or that data were incomplete.

16. Related Tutorials

17. Related Statistical Calculators

18. Sources

Continue through the Clinical Biostats statistical pathway

Use this trial's endpoint as a starting point for deeper study of effect measures, confidence intervals, and sample-size planning.

19. Record Summary

The registry identifies NCT04285489 as a completed, multicenter, retrospective registry study of the Hakim Programmable Shunt System for hydrocephalus. Enrollment is 130. The study began on 2020-05-02, with primary completion on 2020-07-28. Its stated aim was to collect safety information after implantation, with a one-year primary timeframe.

The primary outcome is titled “Number of Participants With Non-infection Within One Year,” but its result and a statistical analysis are not reported in the registry record. The adverse-event group lists 31 participants affected by serious adverse events, 9 affected by other adverse events, and 4 deaths. It also lists several serious-event terms with percentages. The record reports one device arm and no comparator, so these figures are descriptive rather than comparative.

Statistical methods, analysis populations, missing-data handling, and detailed event definitions are not reported in the registry record.

Clinical Biostats