← Clinical Trials
Healthy Phase 1 Registry Results NCT03629223

Bioequivalence of TF3 and TF2 and Effect of Food on the PK of Tepotinib: Complete Statistical Analysis

This analysis examines a randomized, open-label crossover study of tepotinib tablet formulations and the effect of food on tepotinib pharmacokinetics in healthy subjects. It focuses on the primary exposure measure, the registry’s reported geometric-mean ratios and confidence intervals, and the limits of interpreting those results.

Trial start: 2018-08-23  ·  Enrollment: 66  ·  Sponsor: Merck KGaA, Darmstadt, Germany
Scope of this record

This page provides an independent statistical analysis and educational interpretation of publicly reported results. ClinicalTrials.gov provides the official trial registry record. Numerical trial results on this page are restricted to the results posted in the ClinicalTrials.gov record; calculations added by Clinical Biostats are labelled as such.

1. Trial at a Glance

This page covers the registry results for Bioequivalence of TF3 and TF2 and Effect of Food on the PK of Tepotinib (NCT03629223), a randomized phase 1 study. The primary outcome is Part A, B and C: Area Under the Plasma Concentration-Time Curve From Time Zero to the Last Quantifiable Concentration (AUC 0-t) of Tepotinib.

66
Enrollment
Phase 1
6
Arms
In the primary outcome
n/a
Effect
No re-analysis shown
n/a
95% CI
See limitations
FeatureRegistry value
ClinicalTrials.gov identifierNCT03629223
PhasePhase 1
ConditionHealthy
AllocationRandomized
Design modelCrossover
MaskingNone (open label)
Enrollment66
Arms in the primary outcome6
Lead sponsorMerck KGaA, Darmstadt, Germany
Results postedYes

2. Clinical Question

Population

Healthy subjects enrolled in a Phase 1 study. The registry reports an enrollment of 66, while the pharmacokinetic comparisons include different numbers of participants by study part and treatment condition. The precise characteristics of the participants are not reported in the registry record.

Intervention

In Part A, the test treatment was tepotinib tablet formulation TF3, given as a single oral dose of 500 mg. In Part C, the study compared TF3 under fasting and fed conditions. The registry describes TF3 as 2 x 250 mg.

Comparator

Part A compared TF3 with the reference tablet formulation TF2, also given as a single oral dose of 500 mg under fasting conditions. Part B compared TF2 under fasted and fed conditions. Parts B and C therefore assess food effects within each formulation, rather than comparing the formulations with each other.

Primary question

The primary endpoint was tepotinib area under the plasma concentration-time curve from time zero to the last quantifiable concentration, or AUC 0-t. The study asked whether exposure differed between TF3 and TF2 in Part A and how exposure changed between fasted and fed conditions for TF2 in Part B and TF3 in Part C. The registry reports geometric-mean ratios and 90% confidence intervals for these comparisons, but the bioequivalence acceptance limits are not reported in the registry record.

3. Trial Design

This was a Phase 1, randomized, open-label study with a crossover design. It was completed, enrolled 66 participants, and had a primary completion date of 2019-01-25. The registry lists healthy subjects as the study population. Because the design was open-label, masking was not used.

The study had three parts, each addressing a distinct pharmacokinetic comparison. Part A compared the TF3 test formulation with the TF2 reference formulation under fasting conditions. Participants received the two formulations in different orders. Part B compared TF2 under fasted and fed conditions, with treatment order varied. Part C made the corresponding fasted-versus-fed comparison for TF3, again with treatment order varied. The registry descriptions specify single oral doses of 500 mg; for TF3, the dose is described as 2 x 250 mg.

A crossover design means that a participant can contribute observations under more than one treatment condition. The treatment conditions are therefore not necessarily independent groups of different people. The registry reports 38 participants for each Part A pharmacokinetic condition, 12 for Part B fasted, 14 for Part B fed, and 12 for each Part C condition. These condition-specific counts should not be added to infer the number of unique participants.

The registry describes a 21-day washout period in some arm descriptions, but full details of the washout and other design procedures are not reported in the registry record. The allocation sequence generation and the statistical model used for the reported comparisons are also not reported in the registry record.

4. Participant Flow and Accounting

The registry reports how participants moved through each stage of the study. All counts below are exactly as posted; missing counts are not inferred from other stages.

Before assignment: Overall 142 participants were screened in this study. Out of which 66 participants were randomized into the study.

Treatment Period 1 (21 Days)

StagePart A: First Tepotinib TF2 Then TF3Part A: First Tepotinib TF3 Then TF2Part B: First Tepotinib TF2 Fasted Then TF2 FedPart B: First Tepotinib TF2 Fed Then TF2 FastedPart C: First Tepotinib TF3 Fasted Then TF3 FedPart C: First Tepotinib TF3 Fed Then TF3 Fasted
STARTED20206866
COMPLETED20186666
NOT COMPLETED020200

Reasons for not completing this period:

ReasonPart A: First Tepotinib TF2 Then TF3Part A: First Tepotinib TF3 Then TF2Part B: First Tepotinib TF2 Fasted Then TF2 FedPart B: First Tepotinib TF2 Fed Then TF2 FastedPart C: First Tepotinib TF3 Fasted Then TF3 FedPart C: First Tepotinib TF3 Fed Then TF3 Fasted
Adverse Event000100
Lost to Follow-up000100
Benzodiazepines positive010000
Toothache treatment010000

Treatment Period 2 (21 Days)

StagePart A: First Tepotinib TF2 Then TF3Part A: First Tepotinib TF3 Then TF2Part B: First Tepotinib TF2 Fasted Then TF2 FedPart B: First Tepotinib TF2 Fed Then TF2 FastedPart C: First Tepotinib TF3 Fasted Then TF3 FedPart C: First Tepotinib TF3 Fed Then TF3 Fasted
STARTED20186666
COMPLETED19186666
NOT COMPLETED100000

Reasons for not completing this period:

ReasonPart A: First Tepotinib TF2 Then TF3Part A: First Tepotinib TF3 Then TF2Part B: First Tepotinib TF2 Fasted Then TF2 FedPart B: First Tepotinib TF2 Fed Then TF2 FastedPart C: First Tepotinib TF3 Fasted Then TF3 FedPart C: First Tepotinib TF3 Fed Then TF3 Fasted
Did not attend the ambulatory visits100000

Analysis population for the primary outcome, as defined in the registry: Pharmacokinetic.(PK) Analysis Set included participants without any relevant protocol deviations with respect to PK and absence of factors likely to affect comparability of PK results, with adequate trial medication compliance, who had valid primary endpoints for both treatments for Part A; and who had at least 3 post-dose concentration measurements for Part B; C.

5. Baseline Characteristics

The table reproduces the baseline characteristics posted in the registry, which describe the participants analysed at baseline and help show whether the randomized groups were comparable.

Population: The Safety analysis set included all participants who had received at least 1 dose of planned study drug in the respective parts.

CharacteristicUnitPart A: All ParticipantsPart B: All ParticipantsPart C: All ParticipantsTotal
Participants analysed40141266
Age, Categorical: <=18 yearsParticipants0000
Age, Categorical: Between 18 and 65 yearsParticipants40141266
Age, Categorical: >=65 yearsParticipants0000
Sex: Female, Male: FemaleParticipants4105
Sex: Female, Male: MaleParticipants36131261
Ethnicity (NIH/OMB): Hispanic or LatinoParticipants1001
Ethnicity (NIH/OMB): Not Hispanic or LatinoParticipants39141265
Ethnicity (NIH/OMB): Unknown or Not ReportedParticipants0000
Race (NIH/OMB): American Indian or Alaska NativeParticipants0000
Race (NIH/OMB): AsianParticipants1001
Race (NIH/OMB): Native Hawaiian or Other Pacific IslanderParticipants0000
Race (NIH/OMB): Black or African AmericanParticipants1001
Race (NIH/OMB): WhiteParticipants38141264
Race (NIH/OMB): More than one raceParticipants0000
Race (NIH/OMB): Unknown or Not ReportedParticipants0000

6. Primary Endpoint

The registry lists the primary outcome as Part A, B and C: Area Under the Plasma Concentration-Time Curve From Time Zero to the Last Quantifiable Concentration (AUC 0-t) of Tepotinib, measured over Pre-dose, 0.25, 0.5, 0.75, 1, 1.5, 2, 3, 4, 6, 8, 12, 16, 24, 36, 48, 60, 72, 96, 120, 144 and 168 hours post-dose on Day 1 of each treatment period.

ElementRegistry entry
Result typeGeometric Mean
Measure of spreadGeometric Coefficient of Variation
Unitnanograms*hour per milliliter (ng*h/mL)
Endpoint classificationnot reduced to a single comparison

AUC 0-t measures cumulative tepotinib exposure in plasma from dosing until the last sampling time at which the concentration remains at or above the lower limit of quantification. The registry says it was calculated using the mixed log-linear trapezoidal rule. Blood sampling was scheduled at multiple times from pre-dose through 168 hours post-dose on Day 1 of each treatment period.

This endpoint is useful in pharmacokinetic comparisons because it incorporates concentration measurements across time rather than relying on a single concentration. Comparing AUC between formulations can characterize whether total measured exposure is similar, while comparing fed and fasted conditions can characterize the effect of food on exposure. These are pharmacokinetic questions, not direct measures of clinical benefit.

The registry reports geometric means and geometric coefficients of variation for the treatment conditions. It also reports geometric least-squares-mean ratios with 90% confidence intervals for the three comparisons. The analysis population was described as a pharmacokinetic analysis set, with eligibility criteria involving protocol deviations, medication compliance, and valid primary endpoints. The full population description is not reported in the registry record.

7. Why No Re-analysis Is Shown

Reported as posted, not recalculated. Values missing or not estimable for a two-arm comparison (other endpoint). A result is recalculated only when the posted data support a clean two-arm comparison, so no result is shown beyond what the sponsor posted.

8. Statistical Interpretation

Clinical Biostats interpretation

In Part A, the reported geometric-mean ratio for TF3 relative to TF2 was 115.35%, with a 90% confidence interval from 108.55% to 122.58%. This describes the estimated relative AUC 0-t exposure and the uncertainty around that estimate. The interval does not, by itself, establish whether the result meets a bioequivalence criterion: the acceptance limits to be applied are not reported in the registry record.

For TF2, the reported ratio comparing fed with fasted conditions was 186.37%, with a 90% confidence interval from 163.61% to 212.28%. For TF3, the corresponding fed-versus-fasted ratio was 163.15%, with a 90% confidence interval from 146.17% to 182.10%. These estimates describe the registry’s reported direction and scale of the food-condition comparisons; the confidence intervals convey uncertainty in those estimates. They should not be interpreted as randomized comparisons between the two formulations, because each food-effect comparison is within one formulation.

The condition-level geometric means and coefficients of variation provide additional context about the observed exposure distributions. For example, Part A lists geometric means of 16150.0 for TF2 and 18640.0 for TF3, in ng*h/mL. Parts B and C likewise report geometric means for fasted and fed conditions. The geometric coefficients of variation indicate dispersion on the geometric scale; they are not confidence intervals for the treatment ratios.

The confidence intervals are estimates of the range of values compatible with the reported analysis under its statistical assumptions. A narrower interval would indicate greater precision, while a wider interval would indicate more uncertainty. The intervals should be read alongside the study’s crossover structure, the condition-specific sample sizes, and the fact that the statistical method and bioequivalence bounds are not reported in the registry record.

There are no p-values reported for these three comparisons. Their absence does not prevent description of the point estimates and confidence intervals, but it means the record does not provide a reported hypothesis-test result for these outcomes. Nor should the ratios alone be treated as evidence of clinical benefit or harm: the primary endpoint is a pharmacokinetic measure in healthy subjects.

9. Statistical Methods Explained

What does a crossover comparison estimate?

In general, a crossover study compares treatment conditions within participants, with treatment order varied across participants. Each participant can act as a reference for their own response, which can reduce the influence of stable differences between people. The analysis must account appropriately for the paired structure and the treatment sequence. The registry identifies this study as a crossover, but the statistical model and its handling of period or sequence effects are not reported in the registry record.

The Part A comparison concerns TF3 versus TF2 under fasting conditions. Parts B and C instead compare fed with fasted administration within TF2 and TF3, respectively. Keeping these questions separate matters: a food-effect estimate for one formulation is not itself an estimate of the difference between formulations.

How should geometric means and ratios be read?

In general, pharmacokinetic measurements such as AUC are often analyzed on a logarithmic scale because their distributions can be right-skewed and multiplicative differences are often more informative than additive differences. A geometric mean summarizes values on that scale and expresses them back on the original scale. A ratio of geometric means expresses one condition relative to its comparator. A value reported as a percentage of a ratio therefore uses 100% as the point at which the two estimated geometric means are equal.

The registry reports geometric least-squares-mean ratios. Least-squares means are model-based estimates, rather than necessarily being simple arithmetic summaries of the raw observations. The precise model used to obtain these estimates is not reported in the registry record, so the model’s adjustment terms cannot be described from the record.

The geometric coefficient of variation is a measure of variability on a multiplicative scale. In general, greater dispersion can reduce the precision of an estimated comparison, all else being equal. It is distinct from the confidence interval around a ratio: the coefficient of variation describes variability in the observations, whereas the interval describes uncertainty in the estimated comparison.

What information does a confidence interval add?

In general, a confidence interval represents uncertainty around an estimate under the assumptions of the statistical procedure. Its endpoints are not a guarantee that the true value lies within that particular interval, and the interval does not establish practical equivalence on its own. Interpretation depends on the prespecified question and, for a bioequivalence claim, the acceptance limits and analysis rules. Those limits and rules are not reported in the registry record.

The registry reports 90% confidence intervals for all three ratios. It does not report p-values for these comparisons. A confidence interval can still be informative without a p-value: readers can see both the estimated ratio and the range of values compatible with the reported analysis. However, the registry record does not specify the method used to calculate the intervals.

Why does over-dispersion matter?

In general, over-dispersion means that observed variability is greater than a statistical model expects. When a model understates variability, standard errors can be too small and confidence intervals too narrow. A suitable model or robust variance method can address this concern, but the appropriate choice depends on the data and design. The registry record does not report whether over-dispersion was assessed or how variability was handled beyond reporting geometric coefficients of variation.

What can sample-size planning illustrations tell readers?

In general, sample-size planning uses assumptions about the target effect, variability, significance level, allocation, and statistical method to estimate how much information a future study might need. A planning illustration based on an observed effect is not an estimate of the trial’s observed power, and it does not establish what assumptions were used in the original protocol. The registry record does not report the trial’s sample-size justification. The planning assumptions described for the illustrations specify a two-sided significance level of 0.05, equal allocation, and a normal approximation; they are not evidence that these were the design assumptions for the trial.

Because this study has multiple parts and comparisons, a single planning figure would not answer every design question. The pharmacokinetic outcomes, crossover structure, and comparisons differ across parts. The registry does not report the trial’s original power target, variance assumptions, or how its overall enrollment was chosen.

10. Analyses Reported by the Sponsor

MethodEstimate95% CIP-value
not statedPercentage of Ratio of Geometric LS-Mean 115.35108.55 to 122.58not reported
not statedPercentage of ratio of Geometric LS-Mean 186.37163.61 to 212.28not reported
not statedPercentage of ratio of Geometric LS-Mean 163.15146.17 to 182.10not reported

The registry reports the sponsor’s comparison estimates as geometric least-squares-mean ratios with 90% confidence intervals. For Part A, the reported TF3-to-TF2 ratio is 115.35%, with an interval from 108.55% to 122.58%. For Part B, the fed-to-fasted TF2 ratio is 186.37%, with an interval from 163.61% to 212.28%. For Part C, the fed-to-fasted TF3 ratio is 163.15%, with an interval from 146.17% to 182.10%.

No separate recalculated estimate is reported for these comparisons, and no discrepancy between a recalculation and the registry’s analysis is identified. The sponsor’s reported analyses are therefore the available inferential results to interpret. The analysis method is not reported in the registry record, and the confidence intervals should not be reverse-engineered into a different analysis.

The registry does not report p-values or the acceptance limits used to judge bioequivalence. Consequently, the posted ratio and interval describe the estimated relative exposure and its precision, but they do not independently establish that a formal bioequivalence criterion was met. The original statistical analysis plan and its detailed procedures are not reported in the registry record.

11. Multiplicity, Missing Data and Analysis Populations

The registry lists a primary AUC 0-t endpoint across Parts A, B, and C, as well as secondary pharmacokinetic and safety outcomes. It reports 11 outcome measures and 9 analyses, and lists 8 secondary outcomes. The record does not explain how the analyses were grouped into those counts or how the three primary comparisons were treated for inferential purposes.

When multiple outcomes or comparisons are examined, the chance of at least one apparently unusual result can increase if each is tested separately without adjustment. In general, multiplicity procedures can control this issue, or a study can define a hierarchy of primary questions in advance. Whether either approach was used, and whether any adjustment was made, is not reported in the registry record. No p-values are provided for the three reported AUC comparisons, so the record does not show a multiple-testing procedure for them.

The registry describes a pharmacokinetic analysis set and gives some eligibility criteria, including absence of relevant protocol deviations, adequate trial medication compliance, and valid primary endpoints for both treatments in Part A. The full analysis-population description is incomplete in the registry record. The number of participants excluded from each analysis, the handling of incomplete crossover data, and the rules for missing or below-quantification measurements are not reported in the registry record.

In general, missing observations can affect a crossover comparison if missingness is related to treatment, period, participant characteristics, or the measured response. The consequences depend on the extent and pattern of missingness and on the analysis method. The registry record does not report the amount or pattern of missing endpoint data, any imputation procedure, or sensitivity analyses for missing data.

The method used to derive the reported ratios and confidence intervals is also not reported in the registry record. Without the analysis plan, it is not possible to determine whether sequence, period, or other design factors were included, or how protocol deviations were handled beyond the broad analysis-set description.

12. Safety Results

The registry reports serious adverse events as affected participants divided by participants at risk.

ArmParticipants with serious adverse eventsParticipants at riskPercentage
Part A: TF2, Fasted0380.0%
Part A: TF3, Fasted0400.0%
Part B: TF2, Fasted0120.0%
Part B: TF2, Fed1147.1%
Part C: TF3, Fasted0120.0%
Part C: TF3, Fed0120.0%
Participants with at least one serious adverse event
Serious adverse events by armPart A: TF2, Fasted0.0%Part A: TF3, Fasted0.0%Part B: TF2, Fasted0.0%Part B: TF2, Fed7.1%Part C: TF3, Fasted0.0%Part C: TF3, Fed0.0%% of participants with at least one serious adverse event

Deaths

ArmDeaths (participants affected of at risk)
Part A: TF2, Fasted0 of 38
Part A: TF3, Fasted0 of 40
Part B: TF2, Fasted0 of 12
Part B: TF2, Fed0 of 14
Part C: TF3, Fasted0 of 12
Part C: TF3, Fed0 of 12

Other (non-serious) adverse events

Participants with at least one non-serious event at or above the registry's 0% reporting threshold.

ArmParticipants affected of at risk
Part A: TF2, Fasted18 of 38
Part A: TF3, Fasted14 of 40
Part B: TF2, Fasted5 of 12
Part B: TF2, Fed9 of 14
Part C: TF3, Fasted6 of 12
Part C: TF3, Fed6 of 12

Most frequent serious adverse event terms

Event termOrgan systemPart A: TF2, FastedPart A: TF3, FastedPart B: TF2, FastedPart B: TF2, FedPart C: TF3, FastedPart C: TF3, Fed
Femoral neck fractureInjury, poisoning and procedural complications0 of 380 of 400 of 121 of 140 of 120 of 12

Most frequent non-serious adverse event terms

Event termOrgan systemPart A: TF2, FastedPart A: TF3, FastedPart B: TF2, FastedPart B: TF2, FedPart C: TF3, FastedPart C: TF3, Fed
HeadacheNervous system disorders8 of 385 of 401 of 123 of 145 of 121 of 12
DiarrhoeaGastrointestinal disorders3 of 383 of 400 of 122 of 141 of 120 of 12
Abdominal painGastrointestinal disorders1 of 382 of 400 of 123 of 140 of 120 of 12
Oropharyngeal painRespiratory, thoracic and mediastinal disorders0 of 380 of 400 of 122 of 142 of 122 of 12
NasopharyngitisInfections and infestations3 of 380 of 400 of 120 of 141 of 121 of 12
Abdominal pain upperGastrointestinal disorders0 of 381 of 400 of 120 of 141 of 122 of 12
Faeces softGastrointestinal disorders2 of 381 of 400 of 120 of 140 of 120 of 12
FlatulenceGastrointestinal disorders2 of 381 of 400 of 120 of 140 of 120 of 12
Back painMusculoskeletal and connective tissue disorders1 of 381 of 400 of 121 of 140 of 120 of 12
DizzinessNervous system disorders0 of 380 of 401 of 121 of 141 of 120 of 12

Serious events with the highest arm-level rate: femoral neck fracture (7.1%).

Do not overextend the safety comparison. Serious-adverse-event counts are safety observations, not efficacy outcomes, and should not be combined with the primary result into a single benefit-risk number.

The registry reports serious adverse events by treatment condition. It lists no serious events for the Part A TF2 fasted condition (0 of 38), Part A TF3 fasted condition (0 of 40), Part B TF2 fasted condition (0 of 12), Part C TF3 fasted condition (0 of 12), or Part C TF3 fed condition (0 of 12). For Part B TF2 fed, it reports 1 serious adverse event among 14 participants at risk. No deaths are listed for any condition.

The registry also identifies “Femoral neck fracture” as a top serious-event term and associates it with 7.1%. The context and denominator for that percentage are not reported in the registry record, so it should not be treated as a rate for a particular treatment condition without further information.

These are descriptive counts, not estimates of comparative risk. The crossover design means participants may contribute to more than one condition, so condition-level counts do not necessarily represent independent groups. The registry’s counts alone do not establish whether an event was caused by treatment. It also reports non-serious treatment-emergent adverse events, but those counts and serious-event counts should be interpreted separately from the pharmacokinetic results.

13. What the Result Does, and Does Not, Mean

The results describe tepotinib exposure under three study questions: TF3 compared with TF2 under fasting conditions, and fed compared with fasted conditions for each formulation. The reported ratios and confidence intervals quantify the estimated relative AUC 0-t exposure and its uncertainty in the analyzed participants. The condition-level geometric means and coefficients of variation add descriptive information about exposure and variability.

These findings do not by themselves establish whether TF3 and TF2 satisfy a formal bioequivalence standard. That conclusion requires the applicable acceptance limits and prespecified decision rules, which are not reported in the registry record. The findings also do not provide a direct comparison of clinical outcomes, because the primary endpoint is pharmacokinetic exposure and the participants were healthy subjects.

The food-effect estimates indicate the reported relative exposure for fed versus fasted administration within each formulation. They should not be read as a comparison of TF2 against TF3, nor should they be interpreted as a direct measure of how food changes a clinical outcome. The confidence intervals describe statistical uncertainty, not the range of responses for every individual participant.

The safety counts are limited descriptive observations from the recorded study conditions. They do not support broad conclusions about uncommon harms or comparative safety, particularly because the study was a Phase 1 pharmacokinetic investigation and the condition counts can include participants who experienced more than one condition. No deaths were listed, but this is not evidence that an event could not occur outside the observed study.

More broadly, the registry record does not report the full statistical analysis plan, the sample-size justification, or the detailed handling of missing data. Those omissions limit independent assessment of how the reported estimates were produced and how the study’s decision criteria were applied.

14. Why This Trial Matters Statistically

This study is statistically useful because it separates two related but distinct pharmacokinetic questions. Part A addresses relative exposure between two tablet formulations under fasting conditions. Parts B and C address the effect of food within each formulation. Distinguishing these comparisons helps prevent a food-effect result from being misread as evidence about formulation equivalence.

The crossover design also makes the comparison structure important. In general, within-participant comparisons can account for some stable differences between participants, but interpretation depends on the treatment sequence and period structure as well as appropriate analysis. The registry identifies the crossover design and varied treatment orders, while the detailed model is not reported in the registry record.

Reporting both ratios and confidence intervals gives readers more information than a point estimate alone. The point estimate describes the estimated relative exposure; the interval shows the uncertainty around it. The posted intervals are central to judging precision, but they cannot be evaluated against bioequivalence criteria without the criteria themselves.

The registry also illustrates why analysis-population definitions and missing-data rules matter in pharmacokinetic studies. Different numbers of participants are reported across conditions, and the record gives only a partial description of the analysis set. Clearer reporting of participant flow and analysis methods would help readers understand how the crossover observations contributed to each estimate.

Finally, the safety results should remain in context. The registry reports adverse-event counts, but they do not replace the primary pharmacokinetic comparison, and they should not be used to infer treatment causation or generalize beyond the study population.

15. Limitations

The registry record leaves important interpretive details unspecified. It does not report the bioequivalence acceptance limits, the full statistical analysis plan, or the statistical method used to estimate the geometric least-squares-mean ratios and confidence intervals. It also does not report p-values for the AUC comparisons or explain how multiplicity across the study parts was handled.

The analysis population description is incomplete. The record gives some eligibility requirements for the pharmacokinetic set, but not a complete account of the population used for every comparison. It does not report participant flow by part, the number of missing or invalid endpoint measurements, or how incomplete crossover observations were handled. Condition-specific sample sizes therefore need to be read as analysis counts, not as a full account of enrollment and completion.

The registry reports the study as open-label, and the full procedures for allocation, period effects, and sequence effects are not reported in the registry record. The detailed washout information is also incomplete in the arm descriptions. These details matter when assessing a crossover analysis, even though the design and treatment-order variation are described.

The population is described as healthy subjects, limiting how directly these pharmacokinetic findings can be generalized to other populations. The study’s primary outcome is a plasma exposure measure rather than a clinical outcome. In addition, the safety results are descriptive, and the record does not provide enough context for interpreting the listed serious-event term and its associated percentage by treatment condition.

16. Related Tutorials

17. Related Statistical Calculators

18. Sources

Continue through the Clinical Biostats statistical pathway

Use this trial's endpoint as a starting point for deeper study of effect measures, confidence intervals, and sample-size planning.

19. Record Summary

NCT03629223 is a completed Phase 1 randomized, open-label crossover study of tepotinib tablet formulations TF2 and TF3 and the effect of food on tepotinib pharmacokinetics in healthy subjects. It enrolled 66 participants and had a primary completion date of 2019-01-25.

The primary endpoint was AUC 0-t. The registry reports geometric-mean ratios and 90% confidence intervals for TF3 versus TF2 under fasting conditions and for fed versus fasted administration within each formulation. It also reports condition-level geometric means, variability, and adverse-event counts.

The ratios describe relative pharmacokinetic exposure, but the registry does not report the bioequivalence acceptance limits, the full analysis method, or a complete account of missing data and analysis populations. The reported estimates should therefore be interpreted with those limitations in mind.

Clinical Biostats