← Clinical Trials
Cervical Cancer NA Binary Endpoint NCT01706705

Magnetic Resonance Imaging (MRI) Brachytherapy Applicator Study: Complete Statistical Analysis

This analysis examines a single-group study of a novel shielded brachytherapy applicator and imaging for cervical cancer treatment planning. The registry describes an image-quality endpoint, but does not report its outcome count or an analysis estimate.

Trial start: 2012-10-22  ·  Enrollment: 57  ·  Sponsor: M.D. Anderson Cancer Center
Scope of this record

This page provides an independent statistical analysis and educational interpretation of publicly reported results. ClinicalTrials.gov provides the official trial registry record. Numerical trial results on this page are restricted to the results posted in the ClinicalTrials.gov record; calculations added by Clinical Biostats are labelled as such.

1. Trial at a Glance

This page covers the registry results for Magnetic Resonance Imaging (MRI) Brachytherapy Applicator Study (NCT01706705), a na na study. The primary outcome is Number of Participants With Improved Image Quality in the Shifted Position.

57
Enrollment
NA
n/a
Arms
In the primary outcome
n/a
Effect
No re-analysis shown
n/a
95% CI
See limitations
FeatureRegistry value
ClinicalTrials.gov identifierNCT01706705
PhaseNA
ConditionCervical Cancer
AllocationNot applicable (single group)
Design modelSingle Group
MaskingNone (open label)
Enrollment57
Arms in the primary outcomen/a
Lead sponsorM.D. Anderson Cancer Center
Results postedYes

2. Clinical Question

Population

People with cervical cancer were the study population. The registry lists 57 participants enrolled, but does not report further eligibility details or a fuller description of the population included in the primary endpoint analysis.

Intervention

The study evaluated intracavitary brachytherapy treatment planning with a novel MRI-compatible applicator. The registry describes insertion with ultrasound guidance to verify tandem placement in the uterus. The applicator configuration was selected to accommodate the participant’s tumor and vaginal anatomy.

Comparator

This was a single-group study, not a randomized comparison between treatment groups. The primary endpoint description compares images from the shifted and standard applicator positions. That image-position comparison is not the same as a comparison between independently assigned groups.

Primary question

The primary question was how many participants had improved image quality in the shifted position. Image quality was assessed subjectively by a radiation oncologist who did not know the order of the images, and objectively through measurements in the bladder, rectum, and sigmoid. The registry does not report the resulting participant count or analysis.

3. Trial Design

The registry record describes a completed, single-group study of brachytherapy treatment planning for cervical cancer. Its title identifies an MRI brachytherapy applicator study, and the official title describes three-dimensional image-guided intracavitary brachytherapy planning using a novel shielded applicator. The listed sponsor is M.D. Anderson Cancer Center. The phase is recorded as NA.

The enrollment is listed as 57. The study began on 2012-10-22, and its primary completion date is 2018-04-22. The overall status is COMPLETED. These administrative details describe the study record; they do not establish how many enrolled participants contributed usable data to the primary outcome.

The registry lists intracavitary applicator placement, computed tomography (CT), and magnetic resonance imaging (MRI) as interventions. The arm description says that an MRI-compatible applicator was inserted using ultrasound guidance to verify placement of the tandem in the uterus. Tandem and ovoids, tandem and cylinders, or tandem and ring were selected to accommodate the tumor and vaginal anatomy. The description also refers to CT and MRI scans, but further procedural detail is not reported in the registry record.

Allocation is recorded as NA, masking as NONE, and the model as SINGLE GROUP. There is no randomized parallel-group control in the registry description. The primary endpoint instead concerns image quality in shifted versus standard applicator positions. The subjective image assessment is described as blinded to image order; this specific procedure should not be interpreted as masking of the whole study. The registry record does not report a statistical analysis plan, a sample-size justification, or interim analyses.

4. Participant Flow and Accounting

The registry reports how participants moved through each stage of the study. All counts below are exactly as posted; missing counts are not inferred from other stages.

Overall Study

StageExperimental Brachytherapy Treatment Planning
STARTED57
COMPLETED37
NOT COMPLETED20

Reasons for not completing this period:

ReasonExperimental Brachytherapy Treatment Planning
Death1
Lack of Efficacy13
Non-clinical6

5. Baseline Characteristics

The table reproduces the baseline characteristics posted in the registry, which describe the participants analysed at baseline and help show whether the randomized groups were comparable.

CharacteristicUnitExperimental Brachytherapy Treatment Planning
Participants analysed37
Age, Categorical: <=18 yearsParticipants0
Age, Categorical: Between 18 and 65 yearsParticipants35
Age, Categorical: >=65 yearsParticipants2
Age, Continuousyears40 (25 to 94)
Sex: Female, Male: FemaleParticipants37
Sex: Female, Male: MaleParticipants0
Ethnicity (NIH/OMB): Hispanic or LatinoParticipants10
Ethnicity (NIH/OMB): Not Hispanic or LatinoParticipants27
Ethnicity (NIH/OMB): Unknown or Not ReportedParticipants0
Race (NIH/OMB): American Indian or Alaska NativeParticipants0
Race (NIH/OMB): AsianParticipants1
Race (NIH/OMB): Native Hawaiian or Other Pacific IslanderParticipants0
Race (NIH/OMB): Black or African AmericanParticipants2
Race (NIH/OMB): WhiteParticipants34
Race (NIH/OMB): More than one raceParticipants0
Race (NIH/OMB): Unknown or Not ReportedParticipants0
Region of Enrollment: United Statesparticipants37

6. Primary Endpoint

The registry lists the primary outcome as Number of Participants With Improved Image Quality in the Shifted Position, measured over At the time of implant.

ElementRegistry entry
Result typeCount Of Participants
Measure of spreadnot applicable
UnitParticipants
Endpoint classificationBinary Endpoint

The primary endpoint is the number of participants with improved image quality in the shifted position, assessed at the time of implant. It is a participant count, rather than a continuous image-quality score or a clinical outcome. The registry describes subjective and objective assessment of image quality using the novel brachytherapy applicator.

For the subjective assessment, a radiation oncologist compared images taken in the shifted and standard positions without knowing which image came first. Concealing image order can reduce the chance that an assessor’s expectation about sequence influences the comparison. The record does not describe the rating scale, the rule for classifying a participant as improved, or whether any other assessors took part.

The objective assessment was intended to examine reduction in image artifact when the shields were shifted. The bladder, rectum, and sigmoid were contoured, and the average and standard deviation of Hounsfield units within these structures were compared between images. These measurements characterize image values in specified regions; the registry does not report the measurements or a threshold for meaningful improvement.

An image-quality endpoint is relevant to the stated planning question because the study sought to learn whether CT and MRI images could better help plan internal radiation treatment. However, an image-quality count alone does not establish how planning decisions or patient outcomes changed. The registry record does not report the primary endpoint result.

7. Why No Re-analysis Is Shown

Reported as posted, not recalculated. Not a randomized comparison (allocation: NA); arms are not a like-for-like control comparison. A result is recalculated only when the posted data support a clean two-arm comparison, so no result is shown beyond what the sponsor posted.

8. Statistical Interpretation

Clinical Biostats interpretation

The registry describes a technical imaging question: whether image quality improved in the shifted applicator position relative to the standard position. It identifies the primary outcome as a count of participants with improved image quality, and states that subjective and objective assessments were planned. It does not report the count, the denominator analyzed, a measure of uncertainty, or a statistical test. Consequently, the direction and precision of the observed primary result cannot be assessed from the registry record.

The study is single-group and has no randomized control group. Its described within-participant image comparison can address differences between images in the standard and shifted positions, but it does not provide a randomized comparison of patient groups. Even when image comparisons are made within a participant, image acquisition, positioning, image interpretation, and missing image data can affect the result. The record does not provide enough information to assess those issues in detail.

The subjective assessment has a stated safeguard: the radiation oncologist was unaware of which image was first and which was second. That may help limit order-related influence on the judgment. It does not establish that other aspects of image assessment were masked, that assessments were repeated independently, or that a prespecified classification rule was applied. Those details are not reported in the registry record.

The record reports 57 participants enrolled, but that figure should not be assumed to be the primary endpoint denominator. No analyzed population or endpoint denominator is reported. The safety listing has 37 participants at risk in each of its serious and other adverse-event categories; the registry does not explain the relationship between those safety denominators and total enrollment. The primary endpoint result and the extent of missing image data are not reported.

No inferential analyses are listed: the registry reports zero analyses. There are seven outcome measures listed, but no multiplicity procedure or outcome-specific analysis results are reported. The absence of a reported analysis is not evidence that a difference was absent, nor does it establish that the positions were equivalent. It means the record does not provide the results needed to estimate an effect or judge its precision.

Any interpretation should therefore remain at the level of study purpose and design. The record shows that a novel applicator and CT/MRI-based planning were studied, and that the primary question concerned image quality across applicator positions. It does not show how often image quality improved, how large any image-measurement changes were, or whether those changes affected treatment planning. The posted information cannot support a conclusion about the size or reliability of a primary endpoint effect.

9. Statistical Methods Explained

The registry record identifies the primary outcome as a count of participants with improved image quality in the shifted position. It also describes how subjective image review and objective Hounsfield-unit measurements were intended to inform that assessment. The methods below explain how such data are generally interpreted; they should not be read as a claim that any unreported statistical procedure was used in this study.

What does a participant count represent?

A count records how many participants meet a stated outcome definition. To interpret a count as a rate or proportion, the denominator must also be known: the number of participants whose data were eligible for that outcome assessment. Enrollment is not automatically the same as the analysis denominator. Participants may lack usable images or may not have complete assessments, and the registry record does not report whether that occurred. Without a result count and denominator, neither the observed frequency nor its uncertainty can be established.

The outcome definition matters as much as the count. In this study, the registry refers to participants with improved image quality but does not state a rating scale, a decision threshold, or the precise rule used to classify improvement. A count can be reproduced and interpreted consistently only when the classification rule is clear. The record describes image comparisons but does not report those operational details.

How should a within-participant image comparison be understood?

The primary description compares images in shifted and standard positions. When two conditions are assessed within the same participant, the participant serves as their own reference for that comparison. This can account for stable participant characteristics that differ across people. It does not remove possible effects of acquisition order, image quality at baseline, positioning, or assessor judgment. Nor does it create a randomized comparison between treatment groups.

The registry says the radiation oncologist did not know which image was first and which was second when making the subjective comparison. In general, masking image order can reduce the influence of expectations based on sequence. It does not, by itself, establish that the assessor was unaware of every feature that could distinguish images, or that there was agreement between independent assessors. The record does not report those details.

What do the objective image measures add?

The described objective assessment used contours of the bladder, rectum, and sigmoid and compared average and standard deviation of Hounsfield units in those structures. In general, an average describes the central level of measured values in a region, while a standard deviation describes their spread around that average. The study description says these measurements were used to assess reduction in image artifact with shifted shields. The actual measurements, their variability, and any criterion for interpreting them are not reported in the registry record.

Objective measurements can complement subjective review by making the assessment more explicit. They still depend on how regions are contoured, which images are selected, and what comparison is specified. The registry description does not report contouring reliability, repeatability, or a statistical model for these measurements. No particular model or adjustment should therefore be attributed to the study.

What would uncertainty measures mean?

In general, a confidence interval describes a range of effect values compatible with the observed data under the assumptions of the analysis. A narrow interval indicates greater statistical precision than a wide interval, but neither guarantees that the outcome definition or analysis is free of bias. A p-value, when used, summarizes how unusual data would be under a specified null hypothesis and model; it does not measure clinical importance or the probability that a hypothesis is true.

The registry record reports no primary endpoint estimate, confidence interval, or p-value. Thus, there is no posted numerical estimate whose precision or statistical compatibility can be evaluated. A result count without a denominator would not be enough to recover that information, and deriving an estimate from unrelated enrollment or safety figures would be inappropriate.

What can be concluded from the registry’s analysis listing?

The record lists seven outcome measures and zero analyses. This means that outcome descriptions are present but analysis results are not reported in the registry record. It does not reveal whether analyses were conducted elsewhere, how outcomes were selected for analysis, or whether any analysis was prespecified. Those details are not reported in the registry record.

Multiplicity is a general issue when several outcomes or comparisons are assessed. Multiple tests can increase the chance of at least one apparently notable result if each is interpreted separately. Methods to address multiplicity depend on the analysis objectives and prespecified plan. Here, no multiplicity approach is reported, and no effect estimates are available to interpret. It would be unwarranted to infer a particular correction or testing strategy.

How should sample-size illustrations be read?

In general, a sample-size calculation is a planning exercise based on assumptions about an effect, variability, significance level, and desired power. It is not a study result and cannot show that a study had adequate power after the fact. The registry record does not report the trial’s own sample-size justification or analysis plan. Any planning illustration based on an observed effect should not be confused with an observed outcome or with the original design rationale. Since no primary effect estimate is reported, the registry information cannot establish whether the study was planned around a particular image-quality effect.

Overall, the methods description supports understanding of the intended image comparison, but it does not support reconstruction of the analysis. The outcome definition, denominator, observed count, uncertainty, statistical test, and handling of missing observations are not reported in the registry record.

10. Multiplicity, Missing Data and Analysis Populations

The registry lists seven outcome measures and zero analyses. It does not report a multiplicity strategy, such as prioritization of outcomes, adjustment of significance thresholds, or another prespecified approach. General concerns about multiplicity arise when several outcomes or comparisons are examined, but the record does not establish which analyses were conducted or how any findings were interpreted. No correction or testing procedure should be assumed.

The primary endpoint description gives the assessment timing as the time of implant and describes subjective and objective image assessments. It does not report the number of participants with evaluable images, the denominator used for the primary outcome, or the number of incomplete assessments. Missing-data definitions, reasons for missingness, and methods for handling missing observations are not reported in the registry record.

The enrollment is 57, but the record does not identify an analysis population or say that all enrolled participants contributed to every outcome. The safety listing reports 37 participants at risk in each adverse-event category. The relationship between these safety denominators and enrollment is not explained, and they cannot be treated as the primary outcome denominator.

The registry record also does not report an intention-to-treat or per-protocol population, a rule for excluding unusable images, or sensitivity analyses. These omissions limit assessment of how representative any outcome estimate would be, even if a count were available. No outcome estimate is posted, so the influence of missing data or multiplicity on a result cannot be evaluated.

11. Safety Results

The registry reports serious adverse events as affected participants divided by participants at risk.

ArmParticipants with serious adverse eventsParticipants at riskPercentage
Experimental Brachytherapy Treatment Planning0370.0%

Deaths

ArmDeaths (participants affected of at risk)
Experimental Brachytherapy Treatment Planning1 of 37

Other (non-serious) adverse events

Participants with at least one non-serious event at or above the registry's 0% reporting threshold.

ArmParticipants affected of at risk
Experimental Brachytherapy Treatment Planning0 of 37
Do not overextend the safety comparison. Serious-adverse-event counts are safety observations, not efficacy outcomes, and should not be combined with the primary result into a single benefit-risk number.

The registry lists 0 serious adverse events among 37 participants at risk in the experimental brachytherapy treatment-planning group. It also lists 0 other adverse events among 37 participants at risk. A death count of 1 is listed separately. The record does not report a serious adverse-event term or other adverse-event term in the listed top terms.

These figures are safety listings, not results for the primary image-quality endpoint. The separate death listing does not establish that the death was caused by the applicator, imaging, or study procedures. The relationship of the death to the study is not reported in the registry record. Nor does the record provide enough information to determine the timing, circumstances, or completeness of adverse-event follow-up.

The safety denominator is 37, while total enrollment is listed as 57. The registry does not explain this difference, so these safety figures should not be generalized to all enrolled participants. A listing of zero events among those at risk is not proof that no harms occurred outside the recorded category, period, or group. It should be read narrowly as the posted event count and denominator, with the limitations of the registry information in mind.

12. What the Result Does, and Does Not, Mean

The study addresses a technical question about image quality during intracavitary brachytherapy planning for cervical cancer. The registry describes a novel shielded applicator and a comparison of images acquired in shifted and standard positions. It also describes an assessor who was unaware of image order and objective measurements in the bladder, rectum, and sigmoid. These details explain the intended assessment, not its outcome.

The registry record does not report how many participants had improved image quality, the analyzed denominator, the measured Hounsfield-unit values, or an uncertainty estimate. It therefore does not establish the magnitude or precision of any image-quality difference. The absence of a posted result should not be interpreted as evidence of no difference, equivalence, or benefit.

Even a reported improvement in image quality would address an imaging measure, not necessarily the quality of a treatment plan or a patient outcome. The record does not report whether image findings changed treatment planning decisions, nor does it provide a clinical comparison that could establish an effect on health outcomes. No medical conclusion should be drawn from the stated study aim alone.

The single-group design and lack of randomized allocation also constrain what can be inferred. The image-position comparison is described within the study, but the record does not provide a separate randomized control group. Details about the image assessment rules, missing data, and statistical analysis are not reported. In short, the posted information characterizes the question and the planned measurements, while leaving the primary result and its interpretation unresolved.

13. Why This Trial Matters Statistically

This study is statistically interesting because its main question concerns a technical feature of image acquisition and interpretation rather than a conventional comparison of patient outcomes between randomized groups. The endpoint is a count of participants classified as having improved image quality in the shifted position. That classification depends on how improvement is defined, who assesses it, and which participants have evaluable images.

The registry describes two complementary forms of assessment. A radiation oncologist compared images without knowing their order, while objective assessment compared average and standard deviation of Hounsfield units within contoured critical structures. In general, combining subjective judgment with quantitative measurements can provide different perspectives on an imaging question. It does not eliminate the need for clear definitions, reliable measurement, and a transparent analysis plan.

The record also illustrates the distinction between a study’s stated question and a result that can be interpreted statistically. It reports an enrollment of 57 and lists seven outcomes, but no analyses and no primary outcome result. Without an estimate and its denominator, readers cannot judge the size, uncertainty, or consistency of the image-quality finding. Without a reported analysis plan, they also cannot assess whether outcome selection or multiplicity influenced interpretation.

Finally, a technical endpoint should be kept distinct from clinical impact. Image characteristics can be relevant to treatment planning, but an image-quality measure is not itself proof that planning or patient outcomes changed. This distinction is important when reading studies whose primary outcomes are imaging measurements rather than clinical endpoints.

14. Limitations

The main limitation for interpreting this trial is that the registry record does not report the primary endpoint result. There is no count of participants with improved image quality, no endpoint denominator, and no uncertainty estimate. The objective Hounsfield-unit measurements are described, but their values and analyses are not reported. The registry therefore does not permit an estimate of the observed image-quality effect.

The single-group design and allocation recorded as NA mean that the study is not described as a randomized comparison between groups. Its within-participant image-position comparison may inform the stated imaging question, but it does not provide the same evidence as a randomized group comparison. The masking entry is NONE, although the subjective assessment description says the radiation oncologist did not know the image order. The extent of masking beyond that specific assessment is not reported.

The primary endpoint’s classification rule, rating scale, and threshold for improvement are not reported. The record also omits the number of usable image assessments, handling of missing data, and the analysis population. Although seven outcome measures are listed, no analyses or multiplicity approach are reported. The statistical plan, sample-size justification, and interim analyses are not reported in the registry record.

Enrollment is listed as 57, while the safety group lists 37 participants at risk. The record does not explain how these figures relate. The safety information also does not state whether the listed death was related to study procedures. These gaps limit interpretation of both safety coverage and outcome completeness. Further conclusions would require results and methodological detail not reported in the registry record.

15. Related Tutorials

16. Related Statistical Calculators

17. Sources

Continue through the Clinical Biostats statistical pathway

Use this trial's endpoint as a starting point for deeper study of effect measures, confidence intervals, and sample-size planning.

18. Record Summary

The record describes a completed, single-group study of a novel shielded applicator for intracavitary brachytherapy treatment planning in cervical cancer. Enrollment is listed as 57, and the primary outcome is the number of participants with improved image quality in the shifted position at the time of implant.

The outcome description includes subjective comparison by a radiation oncologist unaware of image order and objective Hounsfield-unit measurements in the bladder, rectum, and sigmoid. The registry lists seven outcome measures and zero analyses. It does not report the primary outcome count, denominator, statistical estimate, or uncertainty.

The safety listing reports 0 serious adverse events and 0 other adverse events among 37 participants at risk in each category, with 1 death listed separately. The relationship of the death to the study is not reported in the registry record. The record identifies the study question and measurement approach, but does not provide results sufficient to assess the primary image-quality finding.

Clinical Biostats