This page provides an independent statistical analysis and educational interpretation of publicly reported results. ClinicalTrials.gov provides the official trial registry record. Numerical trial results on this page are restricted to the results posted in the ClinicalTrials.gov record; calculations added by Clinical Biostats are labelled as such.
1. Trial at a Glance
This page covers the registry results for Sensory Stimulation During CIMT (NCT03558230), a randomized na study. The primary outcome is Feasibility (Total Number of Hours That Participants Wear the Device).
| Feature | Registry value |
|---|---|
| ClinicalTrials.gov identifier | NCT03558230 |
| Phase | NA |
| Condition | Cerebral Palsy |
| Allocation | Randomized |
| Design model | Parallel |
| Masking | Quadruple |
| Enrollment | 13 |
| Arms in the primary outcome | 2 |
| Lead sponsor | Medical University of South Carolina |
| Results posted | Yes |
2. Clinical Question
Population
The trial concerns children with cerebral palsy. The registry describes the project as a pilot and lists enrollment of 13 participants. The primary outcome is reported as device-wearing hours, although the outcome population field is blank in the registry record.
Intervention
Participants in the vibration group received wrist stimulation during standardized constraint-induced movement therapy (CIMT). The registry describes the vibration as a behavioral intervention and identifies the device as a generic, commercially available vibrator.
Comparator
The no-vibration group wore the device without vibration during standardized CIMT. Thus, the planned contrast concerns adding wrist vibration while both groups receive CIMT and wear the device.
Primary question
The posted primary endpoint is feasibility, measured as the total number of hours participants wore the device through 5-day study completion. The registry reports a mean and standard deviation for each group. The question reflected by this endpoint is whether participants wore the device for the intended study period; the posted outcome does not directly measure changes in cerebral palsy symptoms or the therapeutic effect of CIMT.
3. Trial Design
This was a randomized, parallel-group pilot trial. The registry reports quadruple masking, but does not identify which participants, staff, assessors, or other parties were masked. Enrollment was 13. The study is listed as completed, with a start date of 2018-07-16 and primary completion date of 2018-10-28. The phase is listed as not applicable.
Both groups received standardized constraint-induced movement therapy and wore a vibration device. The experimental group received wrist stimulation during CIMT; the control group wore the device with no vibration. The registry also lists placebo for vibration and standardized CIMT among the interventions. It describes the device as a generic, commercially available vibrator, not specifically designed for peripheral skin stimulation.
The study's long-term goal was to assess whether sensory stimulation could enhance outcomes of CIMT in children with cerebral palsy. However, the posted primary outcome is feasibility, operationalized as total hours of device wear through 5-day study completion. The registry reports one outcome measure and no secondary outcomes. It lists zero analyses. Details of random-sequence generation, allocation concealment, masking procedures, adherence instructions, and the protocol's sample-size justification are not reported in the registry record.
The arm summaries include 7 participants in the vibration group and 6 in the no-vibration group. The record presents group means and standard deviations for device-wearing hours. It does not post an inferential comparison between groups, such as an estimated contrast with a confidence interval or a test result. Consequently, the design and descriptive endpoint summaries are available, but the registry record does not provide a reported statistical conclusion from a between-group analysis.
4. Participant Flow and Accounting
The registry reports how participants moved through each stage of the study. All counts below are exactly as posted; missing counts are not inferred from other stages.
Overall Study
| Stage | Vibration | No Vibration |
|---|---|---|
| STARTED | 7 | 6 |
| COMPLETED | 7 | 6 |
| NOT COMPLETED | 0 | 0 |
5. Baseline Characteristics
The table reproduces the baseline characteristics posted in the registry, which describe the participants analysed at baseline and help show whether the randomized groups were comparable.
| Characteristic | Unit | Vibration | No Vibration | Total |
|---|---|---|---|---|
| Participants analysed | 7 | 6 | 13 | |
| Age, Continuous | years | 5.7 (SD 1.8) | 5.5 (SD 1.9) | 5.6 (SD 1.8) |
| Sex: Female, Male: Female | Participants | 3 | 6 | 9 |
| Sex: Female, Male: Male | Participants | 4 | 0 | 4 |
| Ethnicity (NIH/OMB): Hispanic or Latino | Participants | 0 | 0 | 0 |
| Ethnicity (NIH/OMB): Not Hispanic or Latino | Participants | 7 | 6 | 13 |
| Ethnicity (NIH/OMB): Unknown or Not Reported | Participants | 0 | 0 | 0 |
| Race (NIH/OMB): American Indian or Alaska Native | Participants | 0 | 0 | 0 |
| Race (NIH/OMB): Asian | Participants | 0 | 1 | 1 |
| Race (NIH/OMB): Native Hawaiian or Other Pacific Islander | Participants | 0 | 0 | 0 |
| Race (NIH/OMB): Black or African American | Participants | 1 | 1 | 2 |
| Race (NIH/OMB): White | Participants | 6 | 3 | 9 |
| Race (NIH/OMB): More than one race | Participants | 0 | 1 | 1 |
| Race (NIH/OMB): Unknown or Not Reported | Participants | 0 | 0 | 0 |
6. Primary Endpoint
The registry lists the primary outcome as Feasibility (Total Number of Hours That Participants Wear the Device), measured over through 5-day study completion..
| Element | Registry entry |
|---|---|
| Result type | Mean |
| Measure of spread | Standard Deviation |
| Unit | Hours |
| Endpoint classification | Continuous Endpoint |
The primary endpoint is the total number of hours participants wore the device through 5-day study completion. It is classified as a continuous measure, reported as a mean with standard deviation, and labeled as a feasibility outcome. Device-wearing time can indicate whether the device was used during the study period, which is relevant when evaluating whether a stimulation procedure can be implemented alongside CIMT.
Feasibility is distinct from clinical benefit. A record of device-wearing hours describes exposure to the device; on its own, it does not show whether vibration changed movement, function, or any other clinical outcome. The registry lists no secondary outcomes, and does not post a clinical endpoint for treatment effectiveness.
The reported means are 28.3 hours for vibration and 27.9 hours for no vibration. Their reported standard deviations are 0.3 and 1.0 hours, respectively. These summaries describe the recorded endpoint within each group. The registry does not specify how device wear was recorded, how missing or incomplete records were handled, or whether the endpoint was assessed by a blinded assessor. Those measurement and analysis details are not reported in the registry record.
7. Why No Re-analysis Is Shown
8. Statistical Interpretation
The posted endpoint summaries describe substantial recorded device wear in both groups during the study period: the vibration group has a mean of 28.3 hours, and the no-vibration group has a mean of 27.9 hours. The standard deviations are 0.3 hours and 1.0 hours, respectively. These are descriptive statistics for the enrolled groups, not an adjusted treatment-effect estimate. No between-group confidence interval, hypothesis-test result, or model estimate is posted, so the precision of a comparative effect cannot be assessed from the registry results.
The primary outcome is feasibility, not a direct measure of clinical benefit. Device-wearing time can describe whether participants used the device, but the registry does not post a clinical outcome that would establish whether vibration altered the effects of CIMT. The trial's stated long-term goal concerns enhancing CIMT outcomes, but the posted primary measure addresses wearing time.
The arm summaries are based on 7 participants assigned to vibration and 6 assigned to no vibration, within a trial with enrollment of 13. With this small pilot enrollment, the descriptive estimates should be read as information about the participants in this study, not as precise estimates for a broader population. A standard deviation describes variation among observations within a group; it is not the uncertainty around a group mean. The registry does not report confidence intervals for the means.
The record lists zero analyses. It therefore does not provide an inferential comparison to support a claim about whether the observed group summaries are compatible with chance variation or represent a reliable difference. No causal conclusion about vibration should be drawn from the descriptive means alone. The registry also does not report details needed to evaluate missing observations, adherence definitions, or the analysis population.
The adverse-event record lists no serious adverse events and no deaths in either group. It lists 2 other adverse events in the vibration group and 1 in the no-vibration group. These counts are descriptive; the registry does not provide event descriptions or an analysis comparing safety between groups. Overall, the posted record gives a small pilot's feasibility summaries and limited adverse-event counts, while leaving comparative uncertainty and clinical outcomes unreported.
9. Statistical Methods Explained
The endpoint is continuous and is summarized using a mean and standard deviation. The mean describes the arithmetic center of the observed device-wearing times in an arm. The standard deviation describes how spread out the individual observations are around that arm's mean. These summaries provide different information: the mean describes a typical level, while the standard deviation describes within-group variability. The reported means are 28.3 hours for vibration and 27.9 hours for no vibration; the standard deviations are 0.3 hours and 1.0 hours, respectively.
What can descriptive summaries establish?
Descriptive statistics characterize the data recorded in the trial. They do not, by themselves, quantify the uncertainty in a difference between randomized groups. A confidence interval is a range of values compatible with the data and the statistical method used, and its width conveys precision. The registry does not post confidence intervals for this endpoint or an estimated group contrast. Without those results, the comparative precision cannot be read from the registry record. The observed means should not be treated as proof that the groups differ or as proof that they are equivalent.
In general, a standard deviation is not a standard error or confidence interval. It reflects the spread of participant-level observations, whereas uncertainty in a mean or contrast also depends on the amount of information and the analysis method. The registry provides the arm counts and standard deviations, but no inferential output. Recalculating an unadjusted test from summary statistics would be a separate analysis, not the sponsor's reported result; no such recalculation is included in the posted results.
Why does randomization matter?
In general, random assignment is intended to make treatment groups comparable in expectation, reducing systematic allocation differences. It does not guarantee balance in every small trial, and it does not eliminate uncertainty. This study is described as randomized and parallel-group. The registry does not report the sequence-generation method or allocation-concealment procedure, so those details cannot be assessed. The record states quadruple masking but does not specify who was masked or how masking was maintained.
Both groups received standardized CIMT and wore the device, while vibration was present in one group and absent in the other. This structure makes the intended contrast the addition of vibration within the CIMT setting. Because the primary measure is device-wearing hours, however, the posted endpoint does not evaluate whether vibration affects a clinical outcome. The registry's long-term project goal and its posted primary endpoint should therefore be kept distinct.
How should variability be considered?
Variability matters because individual participants need not wear the device for identical periods. The reported standard deviations indicate less observed spread in the vibration group than in the no-vibration group, but the small arm counts make both summaries specific to a limited set of observations. In general, when data show greater variability than an analysis model expects, standard errors and tests based on that model can be unreliable; analysts may need methods that accommodate over-dispersion or other features of the data. The registry does not report a model, distributional assessment, or analysis of over-dispersion, and the posted summaries do not establish that such a problem occurred.
What is known about planning and analysis?
The registry does not report the protocol's sample-size justification, a target enrollment rationale, or a prospective power calculation. A planning illustration based on an observed effect is not the same as the trial's original design justification and is not observed power. The registry's planning note describes a two-sided significance level of 0.05, equal allocation, and a normal approximation for such illustrations, with the effect to detect expressed as a stated fraction of the observed effect. It does not identify a prospective effect assumption for this pilot. No numerical planning results are reported in the registry record.
The endpoint is reported as a mean and standard deviation, but the registry does not post a test, confidence interval, adjusted model, or analysis population. It lists zero analyses. Thus, the available statistical evidence is descriptive rather than a reported inferential comparison. General statistical principles can explain what a mean, standard deviation, or confidence interval represents, but they cannot fill in analysis details that the registry does not report.
10. Confidence Intervals for Each Arm
No two-arm comparison is shown for this trial, but each arm's mean can be given with a t-based 95% confidence interval computed from the posted mean, spread and number of participants.
| Arm | Participants | Mean | Standard deviation | 95% CI for the mean |
|---|---|---|---|---|
| Vibration | 7 | 28.300 | 0.300 | 28.023 to 28.577 |
| No Vibration | 6 | 27.900 | 1.000 | 26.851 to 28.949 |
R code and output
arm <- c("Vibration", "No Vibration")
n <- c(7, 6)
m <- c(28.3, 27.9)
sp <- c(0.3, 1)
sd <- sp # posted standard deviations
for (i in seq_along(n)) {
se <- sd[i] / sqrt(n[i]); h <- qt(0.975, n[i] - 1) * se
cat(sprintf("CARM|%s|%d|%.3f|%.3f|%.3f|%.3f\n", arm[i], n[i], m[i], sd[i], m[i] - h, m[i] + h))
}
CARM Vibration 7 28.300 0.300 28.023 28.577
CARM No Vibration 6 27.900 1.000 26.851 28.949
11. Multiplicity, Missing Data and Analysis Populations
Multiplicity arises when several outcomes, time points, or planned comparisons are tested, because repeated testing can increase the chance of a misleading positive result. The registry lists one outcome measure and zero secondary outcomes. It does not report an analysis plan, a hierarchy of endpoints, or a multiplicity adjustment. The record therefore does not establish whether additional outcomes or analyses were planned outside the posted results. The protocol's full multiplicity strategy is not reported in the registry record.
The registry does not describe missing outcome data, withdrawals, exclusions after randomization, or reasons for incomplete device-wear records. Although arm counts and endpoint summaries are posted, those summaries alone do not establish that every enrolled participant contributed a complete observation. The method used to handle missing data is not reported in the registry record.
Similarly, the record does not define an intention-to-treat, per-protocol, or other analysis population. It gives enrollment and arm-level counts, but does not explain whether those counts correspond to all randomized participants, all participants with observed endpoint data, or another analysis set. The analysis population and any exclusions are not reported in the registry record.
These omissions limit evaluation of the statistical process. They do not show that missingness, multiplicity, or exclusions caused bias; rather, the posted record does not contain the information needed to assess those possibilities. No assumptions about the handling of missing data or the scope of planned testing can be made from the available registry entries.
12. Safety Results
The registry reports serious adverse events as affected participants divided by participants at risk.
| Arm | Participants with serious adverse events | Participants at risk | Percentage |
|---|---|---|---|
| Vibration | 0 | 7 | 0.0% |
| No Vibration | 0 | 6 | 0.0% |
Deaths
| Arm | Deaths (participants affected of at risk) |
|---|---|
| Vibration | 0 of 7 |
| No Vibration | 0 of 6 |
Other (non-serious) adverse events
Participants with at least one non-serious event at or above the registry's 0% reporting threshold.
| Arm | Participants affected of at risk |
|---|---|
| Vibration | 2 of 7 |
| No Vibration | 1 of 6 |
Most frequent non-serious adverse event terms
| Event term | Organ system | Vibration | No Vibration |
|---|---|---|---|
| Temporary skin redness | Skin and subcutaneous tissue disorders | 2 of 7 | 1 of 6 |
The registry lists serious adverse events for participants at risk in each group. In the vibration group, 0 of 7 participants had a serious adverse event; in the no-vibration group, 0 of 6 did. The death count is 0 in each group. These are counts recorded during the trial, not estimates of risk beyond the study participants.
The record also lists other adverse events: 2 among 7 participants in the vibration group and 1 among 6 in the no-vibration group. It does not provide descriptions of these events or indicate their severity, timing, or relationship to study procedures. No serious adverse-event terms are listed. The registry does not report a statistical comparison of adverse events between groups.
Zero observed serious events does not demonstrate that serious events are impossible or that the groups have identical safety profiles. The trial enrolled 13 participants, so the safety counts are limited observations. The registry record supports only a description of the events it lists; it does not support a broader safety conclusion.
13. What the Result Does, and Does Not, Mean
The record describes a completed pilot trial comparing wrist vibration with no vibration during standardized CIMT. Its posted primary outcome is device-wearing time through 5-day study completion. Mean wear time is reported as 28.3 hours in the vibration group and 27.9 hours in the no-vibration group. The standard deviations are 0.3 hours and 1.0 hours, respectively. These figures describe the observed endpoint in the two groups.
They do not establish that vibration improved or worsened a clinical outcome. The primary measure concerns device use, not movement, function, or another clinical outcome. Although the project's long-term goal was to assess enhancement of CIMT outcomes, the registry lists no secondary outcomes. No comparative effect estimate, confidence interval, or hypothesis-test result is posted for the primary endpoint.
The trial's randomized design is relevant to the intended comparison, but randomization does not remove uncertainty, particularly in a pilot with enrollment of 13. The registry does not report enough detail to evaluate the allocation process, missing observations, analysis population, or inferential analysis. These are limits on what can be concluded from the posted results, not evidence that any particular design or analysis problem occurred.
The adverse-event record reports no serious adverse events or deaths in either group and lists other adverse events in both groups. Those counts are descriptive and do not establish comparative safety. Taken together, the results document device-wearing summaries and limited adverse-event counts in this pilot. They do not demonstrate clinical benefit, absence of benefit, equivalence between groups, or a definitive safety difference.
14. Why This Trial Matters Statistically
This trial is statistically instructive because its stated long-term objective and its posted primary endpoint address different questions. The project aims to assess whether sensory stimulation can enhance CIMT outcomes in children with cerebral palsy, while the primary measure records total hours of device wear. A feasibility measure can inform whether a study procedure was used, but it cannot substitute for a clinical outcome when the question concerns function or treatment benefit.
The record also illustrates the distinction between descriptive and inferential evidence. Arm means and standard deviations convey observed levels and variability, while a comparative estimate and confidence interval would address the size and precision of a group contrast. The registry does not post those inferential results. Without them, the group summaries should not be turned into a claim that vibration changes device use, much less a clinical outcome.
A small pilot can be useful for assessing procedures and generating information for later research, but limited enrollment also means that the posted summaries describe relatively few participants. The record's lack of a reported sample-size justification or analysis plan further constrains interpretation of how the study was designed to answer its questions. A planning illustration based on an observed effect, if considered, is not evidence of the trial's original power or an observed treatment effect.
Finally, reporting details matter. Information on missing data, analysis populations, measurement procedures, and who was masked would help readers assess potential sources of uncertainty. Their absence from the registry record does not invalidate the descriptive results, but it narrows the claims those results can support.
15. Limitations
- The posted summary statistics are the only data these results rest on; patient-level data, full protocols and statistical analysis plans are not available.
- Recalculated results are simple, unadjusted calculations from posted summaries. They do not replace the sponsor's prespecified analysis.
This pilot enrolled 13 participants, with 7 in the vibration group and 6 in the no-vibration group. The limited enrollment means the arm summaries should be interpreted as describing this study rather than as precise population estimates. The registry does not post confidence intervals or a statistical comparison for the primary endpoint, so the uncertainty around any group contrast is not available.
The outcome is device-wearing time, a measure of feasibility, rather than a direct clinical outcome. The registry lists no secondary outcomes, despite describing a longer-term goal of assessing whether sensory stimulation enhances CIMT outcomes. As a result, the posted outcome does not answer that clinical-effectiveness question.
Several methodological details are not reported in the registry record: the method of random-sequence generation, allocation concealment, the identities of those included in quadruple masking, how device use was measured, the handling of missing observations, the analysis population, and the inferential analysis plan. The record also does not report the protocol's sample-size justification. These gaps limit assessment of bias, precision, and reproducibility, but do not establish that any specific flaw occurred.
The safety data consist of event counts without event descriptions or comparative analysis. The registry reports no serious adverse events and no deaths, but the small number of participants and absence of event details limit what can be inferred from those observations. The record is therefore best read as a limited feasibility report rather than a definitive assessment of clinical outcomes or safety.
16. Related Tutorials
17. Related Statistical Calculators
18. Sources
- ClinicalTrials.gov: Sensory Stimulation During CIMT — NCT03558230.
- Registry record last updated 2019-03-08; status last verified 2018-11.
- Results first posted 2019-03-08.
- Data retrieved from ClinicalTrials.gov on 2026-11-09.
- Group sizes, means, event counts and sponsor-reported p-values are reproduced as posted. Effect estimates, confidence intervals and p-values not attributed to the sponsor are independently calculated from the posted summary statistics.
Continue through the Clinical Biostats statistical pathway
Use this trial's endpoint as a starting point for deeper study of effect measures, confidence intervals, and sample-size planning.
19. Record Summary
NCT03558230, titled Sensory Stimulation During CIMT, is a completed randomized parallel-group pilot sponsored by the Medical University of South Carolina. The registry lists cerebral palsy as the condition, enrollment of 13, quadruple masking, and a phase of not applicable. The start date is 2018-07-16, and primary completion is 2018-10-28.
The trial compared wrist vibration with no vibration during standardized CIMT. The primary feasibility outcome was total device-wearing hours through 5-day study completion, summarized by arm as a mean and standard deviation. The registry lists one outcome measure, no secondary outcomes, and zero analyses. It does not post an inferential comparison, confidence interval, or clinical outcome result.
Serious adverse events and deaths are listed as 0 in each group; other adverse events are listed as 2 in the vibration group and 1 in the no-vibration group. Event descriptions are not reported in the registry record.