Venclose RF Ablation System for the Treatment of IPVs: Complete Statistical Analysis

This analysis concerns a completed, single-group feasibility and safety study of radiofrequency ablation for incompetent perforator veins. The registry record reports short-term safety counts but does not report inferential analyses or numerical results for the listed secondary outcomes.

Trial start: 2020-05-23  ·  Enrollment: 27  ·  Sponsor: Venclose, Inc.
Scope of this record

This page provides an independent statistical analysis and educational interpretation of publicly reported results. ClinicalTrials.gov provides the official trial registry record. Numerical trial results on this page are restricted to the results posted in the ClinicalTrials.gov record; calculations added by Clinical Biostats are labelled as such.

1. Trial at a Glance

This page covers the registry results for Venclose RF Ablation System for the Treatment of IPVs (NCT04386785), a na na study. The primary outcome is Safety: AEs, SAEs, ADEs, SADEs, UADEs.

27
Enrollment
NA
n/a
Arms
In the primary outcome
n/a
Effect
No re-analysis shown
n/a
95% CI
See limitations
FeatureRegistry value
ClinicalTrials.gov identifierNCT04386785
PhaseNA
ConditionChronic Venous Insufficiency
AllocationNot applicable (single group)
Design modelSingle Group
MaskingNone (open label)
Enrollment27
Arms in the primary outcomen/a
Lead sponsorVenclose, Inc.
Results postedYes

2. Clinical Question

Population

Patients with chronic venous insufficiency and incompetent, or refluxing, perforator veins. The registry record describes a feasibility study in patients with these veins; further eligibility details and the characteristics of enrolled participants are not reported in the registry record.

Intervention

Endovascular thermal ablation of incompetent perforator veins using the Venclose RF Ablation System. The intervention is described as radiofrequency thermal ablation. The registry title refers to the Venclose Vestico name, with the commercial name noted as undecided in the official title.

Comparator

There is no comparator group. The study is recorded as a single-group study, with allocation listed as NA. Its results therefore do not provide a randomized or concurrent control comparison.

Primary question

The primary question concerns safety: what adverse events and device-related adverse effects were observed during the 3-day post-procedure timeframe? The named safety categories include adverse events, serious adverse events, adverse device effects, serious adverse device effects, and unanticipated adverse device effects. The registry record does not report a comparative treatment effect.

3. Trial Design

This was a completed, investigator-initiated safety study of the Venclose RF Ablation System for treatment of incompetent perforator veins. The record describes it as a feasibility study in patients with refluxing perforator veins and lists chronic venous insufficiency as the condition. The intervention was endovascular thermal ablation in a single group. Enrollment is recorded as 27.

The design is listed as single-group, with allocation NA and no masking. There is no concurrent control arm, and the record does not describe random assignment. This matters because the study can describe events observed among treated participants, but it cannot estimate a treatment-versus-control difference from its own design. The record lists phase as NA.

The study start date is 2020-05-23, the primary completion date is 2021-04-13, and status is COMPLETED. These dates describe the registry timeline; they do not establish when each participant entered, completed follow-up, or contributed data. Participant-level timing and analysis-population details are not reported in the registry record.

The primary outcome is safety, expressed as events in the 3-day post-procedure timeframe. The description says procedure-related adverse events and device effects would be monitored and analyzed for acceptability after the study. The registry record lists 13 outcome measures, including labels related to acute ablation success and reflux, but does not give numerical results for those outcomes in the information recorded. It lists 0 analyses. The formal statistical analysis plan, eligibility criteria, and sample-size justification are not reported in the registry record.

4. Participant Flow and Accounting

The registry reports how participants moved through each stage of the study. All counts below are exactly as posted; missing counts are not inferred from other stages.

Overall Study

StageSingle-arm: Endovascular Thermal Ablation in IPV
STARTED27
COMPLETED27
NOT COMPLETED0

5. Baseline Characteristics

The table reproduces the baseline characteristics posted in the registry, which describe the participants analysed at baseline and help show whether the randomized groups were comparable.

CharacteristicUnitSingle-arm: Endovascular Thermal Ablation in IPV
Participants analysed27
Age, Continuousyears67.8 (SD 14.2)
Sex: Female, Male: FemaleParticipants11
Sex: Female, Male: MaleParticipants16
Region of Enrollment: United Statesparticipants27
Weightpounds235.2 (SD 53.6)
Heightinches66.7 (SD 18.5)
Body Mass Index (BMI)kg/m^237.1 (SD 7.9)
Number of Veins: FemaleIPVs14
Number of Veins: MaleIPVs16
CEAP Classification: C0IPVs0
CEAP Classification: C1IPVs0
CEAP Classification: C2IPVs0
CEAP Classification: C3IPVs0
CEAP Classification: C4IPVs13
CEAP Classification: C5IPVs7
CEAP Classification: C6IPVs10

6. Primary Endpoint

The registry lists the primary outcome as Safety: AEs, SAEs, ADEs, SADEs, UADEs, measured over 3-day post-procedure.

ElementRegistry entry
Result typeNumber
Measure of spreadnot applicable
UnitEvents
Endpoint classificationnot reduced to a single comparison

The primary endpoint is a safety assessment covering adverse events, serious adverse events, adverse device effects, serious adverse device effects, and unanticipated adverse device effects. Its unit is events, and its specified timeframe is 3-day post-procedure. The record describes monitoring procedure-related events and device effects for post-study assessment of acceptability.

Safety endpoints are used to characterize potential harms observed during and after a procedure. Event categories distinguish general adverse events from events considered serious or related to the device, although the registry description does not provide category definitions or attribution rules. Because the outcome is expressed as events, event counts and counts of affected participants are not automatically interchangeable: a participant may experience more than one event. The available registry summary does not provide enough detail to determine how recurrent events were handled in the primary outcome.

The short stated timeframe focuses the endpoint on immediate post-procedure safety. It does not, by itself, describe later safety experience. The record does not report a prespecified threshold for acceptability, a formal hypothesis test, or a numerical primary-endpoint result broken down by the named categories. The adverse-event summary does report affected-participant counts; those counts should be read as descriptive safety information rather than as a comparative estimate.

7. Why No Re-analysis Is Shown

Reported as posted, not recalculated. Not a randomized comparison (allocation: NA); arms are not a like-for-like control comparison. A result is recalculated only when the posted data support a clean two-arm comparison, so no result is shown beyond what the sponsor posted.

8. Statistical Interpretation

Clinical Biostats interpretation

The registry record describes a single-group study with enrollment of 27 and a primary safety timeframe of 3-day post-procedure. Its adverse-event summary records 27 at risk, 0 affected by serious adverse events, 0 affected by other adverse events, and 0 deaths. These are descriptive counts in the registry summary. They do not show how the safety experience compares with another treatment or with no procedure.

A zero recorded count is not evidence that the underlying risk is zero. It means that the registry summary records no affected participants in the corresponding category during the reported assessment. Interpretation also depends on how events were collected, classified, attributed, and followed. Those operational details are not reported in the registry record. The timeframe is limited to 3-day post-procedure for the primary outcome, so these figures should not be generalized to later periods.

The primary outcome is framed as event counts, whereas the adverse summary reports counts of affected participants. Without category-level event totals and further details on repeated events, these summaries cannot establish the number of all events or the distribution of events per participant. The record does not provide confidence intervals, hypothesis tests, adjusted estimates, or numerical primary results for each listed safety category. Accordingly, the displayed safety counts do not support a precise estimate of the event rate or a claim about comparative safety.

The registry lists acute ablation success and reflux among secondary outcome labels, but numerical values for these outcomes are not reported in the registry record. The record lists 13 outcome measures and 0 analyses. No analysis results for effectiveness, changes over time, or associations with participant characteristics are therefore available in the recorded information. The absence of a reported analysis is not a finding of no effect; it means an estimate cannot be interpreted from this record.

Sample-size planning illustrations, if considered alongside these results, are hypothetical planning calculations rather than observed power. The stated illustration assumptions use a two-sided significance level of 0.05, equal allocation between two arms, and a normal approximation, while the actual trial is single-group. They cannot be read as the design used in this study or as evidence that the study had a particular probability of detecting an effect. The record does not report the trial's own sample-size justification or an observed treatment effect on which to base a comparative interpretation.

Overall, the recorded figures describe short-term safety observations in the treated group. With no control group and no reported inferential results, they do not estimate a causal treatment effect. The small scope of the recorded follow-up and the missing details about outcome collection further limit conclusions. The study record is useful for understanding what was monitored and what counts were entered, but it does not answer comparative questions about safety or provide numerical results for the listed secondary outcomes.

9. Statistical Methods Explained

What does a single-group design estimate?

In general, a single-group study describes outcomes observed among participants who receive the intervention. It can report counts, proportions, or other summaries for that group if those results are available. It cannot, on its own, separate changes associated with treatment from changes that might have occurred over time, from other care, or from characteristics of the enrolled participants. A comparison requires a suitable reference group or another defensible design for estimating what would have happened without the intervention.

For this study, allocation is listed as NA, masking as NONE, and the model as SINGLE GROUP. There is no like-for-like control comparison. As a result, the registry's safety summary should be read descriptively. It does not produce a relative risk, risk difference, or comparative treatment estimate. Such estimates would require a comparison group and the relevant outcome data, neither of which is recorded for this study.

What does an event count tell the reader?

In general, an event count is the number of events recorded under a defined outcome and observation period. It is distinct from the number of participants who experienced an event. A participant can have multiple events, and an event may be counted under more than one category if the protocol's definitions allow that. For meaningful interpretation, readers need the event definitions, attribution rules, collection procedures, and handling of recurrent events.

The primary endpoint is specified in events, with a 3-day post-procedure timeframe. The adverse-event summary gives counts of affected participants in the serious, other, and death fields, rather than a detailed event-level breakdown. The registry record does not report how event-level data were summarized for the primary endpoint, whether multiple events per participant were counted separately, or how device relatedness was assessed. The participant counts therefore should not be treated as a complete event-count distribution.

Why do uncertainty intervals matter?

In general, a confidence interval gives a range of values compatible with the observed data under a specified statistical model. Its width reflects statistical uncertainty as well as the amount and variability of information available. A narrow interval indicates greater precision under that model; a wide interval indicates less precision. A confidence interval is not a guarantee that the true value lies within its limits, and it does not correct for biased outcome collection or an unsuitable design.

The registry record does not report confidence intervals for the safety summaries. Without an interval or another uncertainty measure, the zero counts cannot be translated into a precise upper bound on risk from the information recorded. In particular, the count does not demonstrate that rare events cannot occur. The interpretation is also restricted by the stated short-term timeframe and by the absence of reported details about completeness of follow-up.

What would an inferential analysis require?

In general, an inferential analysis begins with a defined estimand: the outcome, population, treatment condition, comparison, and time point of interest. It then specifies the statistical model and how the analysis handles missing observations, repeated measurements, departures from distributional assumptions, and multiplicity. A reported estimate is most useful when accompanied by its uncertainty and a clear description of the analysis population.

The registry record lists 0 analyses and does not report a statistical analysis plan, analysis population, confidence intervals, or hypothesis-test results. The primary outcome description states that events would be monitored and analyzed for acceptability, but it does not specify a numerical acceptability threshold or inferential procedure. No particular model, adjustment, or missing-data method should be inferred from that wording.

General statistical concepts such as over-dispersion matter when counts vary more than a chosen count model expects; accounting for that variability can change uncertainty estimates. However, the record does not describe a count model or provide event-level data that would support evaluating over-dispersion. It would be inappropriate to claim that such a method was used or was necessary in this analysis.

How should planning calculations be read?

In general, a sample-size calculation is a prospective planning tool. It relates a target effect, outcome variability, significance criterion, allocation, and desired power to a planned amount of information. It is not a result from enrolled participants. Post hoc calculations sometimes use an observed effect, but those do not establish observed power or replace an estimate with an uncertainty interval.

The stated planning illustration uses a two-sided significance level of 0.05, equal allocation between two arms, and a normal approximation. That setup is not a description of this single-group trial. Any such illustration should be read only as a hypothetical planning scenario and not as the design actually used, as observed power, or as evidence of a treatment effect. The registry record does not report a trial-specific sample-size justification, and the effect size and planning outputs are not recorded in the registry entries.

10. Multiplicity, Missing Data and Analysis Populations

The registry lists 13 outcome measures, with labels that include acute ablation success and reflux. It does not report a multiplicity strategy, such as a hierarchy of outcomes, an adjustment for multiple testing, or a rule for interpreting several tests together. Without those details and without reported outcome analyses, it is not possible to assess how multiplicity may have been handled. In general, testing many outcomes can increase the chance of apparently notable findings arising by chance; a prespecified plan helps readers distinguish confirmatory from exploratory analyses.

The record lists 0 analyses. Numerical results and inferential analyses for the secondary outcomes are not reported in the registry record. The record also does not report an analysis population, participant flow through follow-up, missing-data counts, reasons for missingness, or a method for handling missing observations. It is therefore not possible to determine whether all enrolled participants contributed to each outcome or whether the analysis used an intention-to-treat, per-protocol, or other population.

In general, missing data can affect interpretation when the likelihood of an observation being missing is related to a participant's health, experience, or outcome. Statistical approaches depend on the amount and pattern of missingness and on assumptions that should be stated. No particular missing-data mechanism or method can be inferred for this study. These omissions limit assessment of completeness and robustness; they do not establish that data were missing or that a particular bias occurred.

11. Safety Results

The registry reports serious adverse events as affected participants divided by participants at risk.

ArmParticipants with serious adverse eventsParticipants at riskPercentage
Single-arm: Endovascular Thermal Ablation in IPV0270.0%

Deaths

ArmDeaths (participants affected of at risk)
Single-arm: Endovascular Thermal Ablation in IPV0 of 27

Other (non-serious) adverse events

Participants with at least one non-serious event at or above the registry's 0% reporting threshold.

ArmParticipants affected of at risk
Single-arm: Endovascular Thermal Ablation in IPV0 of 27
Do not overextend the safety comparison. Serious-adverse-event counts are safety observations, not efficacy outcomes, and should not be combined with the primary result into a single benefit-risk number.

The registry's safety summary lists 27 at risk in the single treatment group. It records 0 participants affected by serious adverse events, 0 affected by other adverse events, and 0 deaths. These are the posted counts for the categories in the adverse summary; they are not a comparison against an untreated or alternative-treatment group.

Read the zero counts as no affected participants recorded in those summary categories, not as proof that the underlying risk is absent. The primary safety timeframe is 3-day post-procedure. The record does not report event-level totals, detailed definitions, completeness of follow-up, or category-specific confidence intervals. It also does not list specific serious event terms. Those omissions make it difficult to assess how comprehensively events were captured or how precisely the counts characterize risk.

The endpoint description includes several categories of adverse events and device effects, but the summary available for interpretation does not separately quantify every named category. Participant counts and event counts may differ when a participant experiences repeated events. The available figures should therefore be treated as short-term descriptive safety information, not as a complete account of all events or as evidence of comparative safety.

12. What the Result Does, and Does Not, Mean

The result that can be read from the registry is a short-term safety summary for a single group treated with endovascular thermal ablation. The adverse-event record lists 27 at risk and records 0 affected by serious adverse events, 0 affected by other adverse events, and 0 deaths. The study is marked completed, and its primary safety timeframe is 3-day post-procedure.

Those counts do not establish that treatment is safe or unsafe, and they do not estimate how the safety experience differs from another approach. There is no randomized or concurrent control group. The counts also do not establish that the risk of an event is zero: they describe what was recorded in this study summary and within its stated timeframe. Details needed to evaluate event ascertainment and follow-up completeness are not reported in the registry record.

The registry record does not provide numerical results for the listed acute ablation success or reflux outcomes, and it lists 0 analyses. It therefore does not support conclusions about the magnitude, precision, or statistical significance of changes in those outcomes. The existence of an outcome label is not itself evidence that the outcome improved, worsened, or remained unchanged.

In general, a feasibility study can provide descriptive information about whether a procedure and its outcome monitoring were undertaken in a clinical study. Its findings can inform questions for further research, but they are not a substitute for a controlled comparison when the question concerns relative effects. Here, the record does not report the protocol details, sample-size justification, or inferential plan needed to evaluate such questions.

Sample-size planning illustrations are prospective or hypothetical calculations, not observed power and not evidence of treatment effect. The stated illustration assumptions use equal allocation between two arms, whereas the recorded study has a single group. The illustrations therefore should not be interpreted as a description of the actual trial design. The appropriate conclusion is limited: the registry records the stated short-term safety counts, while comparative efficacy and broader or longer-term safety remain unestablished by the information recorded.

13. Why This Trial Matters Statistically

This study is statistically notable for the gap between its safety objective and the information available for estimating uncertainty. A registry can identify the outcome categories and observation timeframe, and it can report observed counts. For interpretation, however, readers also need detailed outcome definitions, event-level summaries, the analysis population, and uncertainty measures. Those details are not reported in the registry record.

The single-group design is central to what can be learned. It allows the record to describe observations after the intervention, but it does not provide a concurrent control against which to interpret those observations. Even a complete count of events would not by itself isolate the effect of the device from other explanations. This distinction is important whenever descriptive safety data are discussed alongside claims about comparative effects.

The record lists 13 outcome measures and 0 analyses. The absence of reported numerical results for the secondary outcomes makes it impossible to assess their size or precision and leaves multiplicity handling unclear. A prespecified analysis strategy and transparent reporting of estimates and uncertainty would help readers understand which questions the study could address and how strongly the data support each answer.

The planning assumptions also illustrate why design context matters. The stated planning calculation assumes equal allocation between two arms, while the actual record describes a single group. A hypothetical calculation under those assumptions cannot be treated as a description of this study or as observed power. Clear separation of planning scenarios from analyses of enrolled participants helps prevent readers from mistaking a design illustration for evidence.

In general, these issues do not invalidate descriptive counts. They define their scope. The study's recorded safety summary can be read as a report of observed short-term categories, while the design and reporting gaps limit precision, comparability, and conclusions about outcomes not numerically reported.

14. Limitations

The single-group design has no concurrent comparator, so it cannot estimate a treatment-versus-control difference. Allocation is listed as NA and masking as NONE. This limits causal interpretation and may leave outcome assessment open to expectation or classification effects, although the registry record does not describe whether those effects occurred.

The stated primary safety timeframe is 3-day post-procedure. The record does not report longer-term safety results or numerical results for the listed acute ablation success and reflux outcomes. Its adverse summary provides affected-participant counts, but the primary endpoint is expressed in events; event-level totals and the handling of repeated events are not reported in the registry record.

Important design and analysis details are also absent. Eligibility criteria, baseline participant characteristics, follow-up completeness, missing-data handling, outcome definitions, device-relatedness rules, the statistical analysis plan, and a trial-specific sample-size justification are not reported in the registry record. The record lists 0 analyses, so there are no reported estimates or uncertainty intervals for assessing precision. These reporting gaps make it difficult to judge representativeness, completeness, and the robustness of the recorded counts.

The study is described as a feasibility and safety study, and its enrollment is 27. The registry summary should not be used to infer a rate beyond the recorded categories and timeframe. A zero count does not show that rare outcomes are impossible, and no conclusion about comparative effectiveness or safety follows from these data alone. The stated sample-size planning assumptions describe a hypothetical two-arm illustration rather than the single-group study design.

15. Related Tutorials

16. Related Statistical Calculators

17. Sources

Continue through the Clinical Biostats statistical pathway

Use this trial's endpoint as a starting point for deeper study of effect measures, confidence intervals, and sample-size planning.

18. Record Summary

The registry record describes NCT04386785, titled Venclose RF Ablation System for the Treatment of IPVs. It is a completed, investigator-initiated, single-group feasibility and safety study of radiofrequency thermal ablation for incompetent perforator veins in patients with chronic venous insufficiency. Enrollment is recorded as 27. Allocation is NA, masking is NONE, and phase is NA.

The primary outcome concerns adverse events and device effects during the 3-day post-procedure timeframe. The adverse summary records 27 at risk, 0 affected by serious adverse events, 0 affected by other adverse events, and 0 deaths. The registry lists 13 outcome measures and 0 analyses. Numerical results for the listed secondary outcomes, inferential analyses, and a formal statistical plan are not reported in the registry record. With no control group, the recorded safety counts are descriptive and do not establish comparative effects.