Tutorials › Physiologically-Based Pharmacokinetics (PBPK) › Joint Constraints on Organ Volumes and Blood Flows

Biological Plausibility and Parameter Uncertainty · Tutorial 156 of 799

Joint Constraints on Organ Volumes and Blood Flows

Learn to check whether organ volumes and blood flows satisfy shared whole-body constraints while preserving plausible organ-level relationships.

Advanced 11 min read

What You'll Learn

  • Define consistent, nonoverlapping compartments before summing organ volumes.
  • Check that modeled volumes account for the declared whole-body volume.
  • Reconcile systemic organ flows with cardiac output without double counting portal or pulmonary flow.
  • Calculate organ perfusion per unit volume and interpret it in context.
  • Diagnose discrepancies that persist even when whole-body totals balance.
  • Distinguish an accounting correction from a physiologically justified parameter change.

Why Organ Volumes and Flows Must Be Checked Together

A PBPK parameter set can contain individually plausible organ volumes and blood flows yet still describe no coherent physiology. Organ volumes must fit within the modeled body, and systemic organ perfusion must be consistent with cardiac output. In addition, a flow assigned to an organ should be considered in relation to that organ’s volume and to how its blood supply is represented. These are joint constraints: passing one check does not imply passing the others.

The audit is meaningful only when the inputs refer to the same population or individual, physiological state, and unit system. It also depends on a clear compartment definition. A PBPK tissue compartment usually represents the tissue as a whole, including its local vascular space; adding a separate whole-body blood volume to those tissue volumes can therefore double count volume. Model conventions differ, so determine what each volume includes before calculating a total.

Definition: A set of modeled organ and tissue volumes satisfies the whole-body volume constraint when the volumes of mutually exclusive compartments, including any explicitly modeled remainder compartment, sum to the declared total body volume. A set of systemic organ blood flows satisfies the cardiac-output constraint when each systemic delivery of cardiac output is counted exactly once and the resulting total equals cardiac output, \(Q_{\mathrm{CO}}\), under the stated steady-state assumptions.

The volume check assumes that compartments are nonoverlapping and collectively represent the declared body-volume target. The flow check assumes a closed circulation at steady state, with no unmodeled shunt, net accumulation, or mismatch in measurement state. These assumptions should be reviewed rather than silently presumed. If the parameter set represents only selected organs, the remainder must be identified; the listed organs alone need not sum to the whole body.

Writing the Joint Constraints

Let \(V_i\) denote the volume of modeled compartment \(i\), and let \(V_{\mathrm{body}}\) denote the body-volume target under the model’s convention. If the compartments form an exhaustive, nonoverlapping partition, the accounting condition is:

$$ \sum_{i=1}^{m} V_i = V_{\mathrm{body}}. $$

If only selected compartments are listed, their sum should not exceed the declared target, and the unrepresented volume should be assigned to a defined remainder rather than treated as unexplained slack. If the input is body mass rather than body volume, do not equate kilograms and liters without stating the density assumption or conversion convention.

For systemic perfusion, let \(Q_i\) be the flow assigned to each mutually exclusive systemic destination. Under steady-state circulation, conservation of flow gives:

$$ \sum_{i=1}^{k} Q_i = Q_{\mathrm{CO}}. $$

The pulmonary circulation is not an additional systemic destination to add to this sum: in a closed circulation, pulmonary flow also equals cardiac output. Likewise, blood entering an organ through a secondary route must not be counted as a second independent contribution from the heart if that blood has already been counted upstream.

Volume and flow totals are necessary but not sufficient. For each organ with a defined perfusion, calculate its flow per unit volume:

$$ q_i = \frac{Q_i}{V_i}. $$

Here \(q_i\) has units such as L/min/L. This ratio can expose a misassigned flow or volume that is hidden by correct totals. It is not a universal constant or a stand-alone pass/fail threshold: expected values depend on organ, species, age, physiological state, and the definition of perfusion used. Compare it with an appropriate source or model-specific reference, not with an assumed universal ratio.

A Short Derivation of the Flow Balance

At steady state, consider the systemic circulation as a control volume. Blood leaving the heart and entering systemic tissues is \(Q_{\mathrm{CO}}\). If there is no net blood accumulation in the circulation, total systemic outflow from those tissues must return to the heart at the same rate. With each systemic destination counted once, summing its inflow gives the cardiac-output constraint. The equality is therefore a conservation statement, not a claim that all organs receive the same flow.

$$ \text{systemic inflow} = \sum_{i=1}^{k} Q_i = \text{systemic return} = Q_{\mathrm{CO}}. $$

This derivation also explains why the definition of an “organ flow” matters. For example, portal blood is first delivered to portal-drained tissues and then passes to the liver. It is a flow to the liver tissue, but it is not a second independent delivery from the heart. A consistent accounting scheme can sum primary systemic destinations, or use another explicitly defined scheme; it cannot mix the two by counting the portal flow both before and after its passage through the portal system.

Worked Example: Checking Whole-Body Volume and Cardiac Output

Suppose a hypothetical adult PBPK parameter set declares a whole-body volume target of 70.0 L and a cardiac output of 5.20 L/min. Its mutually exclusive volume compartments and systemic perfusion assignments are as follows. The remaining-tissue compartment includes all tissues not separately listed.

CompartmentVolume (L)Systemic flow (L/min)
Liver1.501.45
Kidneys0.3001.05
Muscle28.00.900
Adipose tissue14.00.200
Remaining tissues26.21.60

Volume check. The listed volumes sum to \(1.50+0.300+28.0+14.0+26.2=70.0\) L, matching the declared target. This check is valid because the example stipulates that the compartments are nonoverlapping and exhaustive.

Flow check. The systemic flows sum to \(1.45+1.05+0.900+0.200+1.60=5.20\) L/min, matching cardiac output. The liver’s 1.45 L/min is its total flow, including both hepatic arterial and portal contributions; those components must not also be counted as separate systemic destinations in this same sum.

Organ-specific check. The flow per unit volume is \(1.05/0.300=3.50\) L/min/L for the kidneys and \(1.45/1.50=0.967\) L/min/L for the liver. These calculations are useful audit quantities, but the totals alone do not establish that either ratio is appropriate. That judgment requires a relevant reference for the same species, state, and flow definition.

Portal Flow and Other Accounting Traps

The portal system is a particularly important source of double counting. A model may report blood flow to the gut and also report total hepatic inflow, which includes portal venous return. Those values describe different stages of blood’s route, not two independent cardiac deliveries. When checking total systemic flow, use one internally consistent accounting convention and document which flows are included.

Worked Example: Avoiding Double Counting of Portal Blood

A hypothetical model has cardiac output of 5.00 L/min. Primary systemic destinations are assigned 1.00 L/min to portal-drained tissues, 0.350 L/min through the hepatic artery, 0.900 L/min to the kidneys, 0.800 L/min to muscle, and 1.95 L/min to other tissues.

Primary-destination accounting. The sum is \(1.00+0.350+0.900+0.800+1.95=5.00\) L/min. The systemic flow balance is satisfied.

The liver receives both hepatic arterial flow and portal return, so its total inflow is \(0.350+1.00=1.35\) L/min. If the analyst replaces the hepatic arterial entry with total liver inflow but retains the portal-drained-tissue entry, the sum becomes \(1.35+1.00+0.900+0.800+1.95=6.00\) L/min. The apparent 1.00 L/min excess is exactly the portal flow counted twice, not evidence that cardiac output should be increased.

For an organ-level liver perfusion calculation, 1.35 L/min may be the relevant liver inflow. For a whole-system accounting check, the portal flow must be counted only once. The analyst should keep those two purposes distinct.

Balanced Totals Can Still Hide Implausible Assignments

Passing both sum checks does not validate the allocation among organs. One organ can be assigned too little flow while another receives too much, leaving cardiac output unchanged. Similarly, an organ volume can be too large while a remainder compartment is too small, preserving the whole-body total. A joint audit therefore has at least three stages: check definitions and coverage, check sums, and then inspect organ-specific relationships.

The following example uses an explicitly hypothetical project reference. It is not a universal physiological range. Its purpose is to show how to interpret a discrepancy and why an arithmetic adjustment alone does not establish the correct physiology.

Worked Example: Detecting a Flow Allocation Error Despite a Balanced Total

A hypothetical model has a declared cardiac output of 5.00 L/min. Its volumes are 1.50 L for liver, 0.300 L for kidneys, 25.0 L for muscle, 18.0 L for adipose tissue, and 25.2 L for remaining tissues, summing to 70.0 L. The corresponding flows are 1.20, 0.150, 1.40, 0.200, and 2.05 L/min.

Check the totals. The flows sum to \(1.20+0.150+1.40+0.200+2.05=5.00\) L/min, so the cardiac-output constraint is met. The listed volumes also sum to \(1.50+0.300+25.0+18.0+25.2=70.0\) L.

Check the renal allocation. Renal flow is only \(0.150/5.00=0.0300\), or 3.00% of cardiac output. Suppose the project’s stated reference for this same modeled population and state is 18% to 25%. That reference corresponds to \(0.18(5.00)=0.900\) to \(0.25(5.00)=1.25\) L/min. The assigned 0.150 L/min is outside this project-specific range. The kidney flow per unit volume is \(0.150/0.300=0.500\) L/min/L.

A bookkeeping substitution of 1.00 L/min for renal flow, offset by reducing remaining-tissue flow from 2.05 to 1.20 L/min, would preserve cardiac output: \(1.20+1.00+1.40+0.200+1.20=5.00\) L/min. This demonstrates a possible reallocation, not proof that it is correct. The underlying source, organ definitions, and physiological state must be checked before changing the model.

Practical Audit Sequence and Failure Modes

A useful audit separates hard accounting identities from reference-dependent plausibility checks. The first two are usually exact within the declared model convention; organ-specific comparisons depend on suitable source data and matching definitions.

1
Standardize definitions and units.
Confirm species, population, physiological state, units, and what each compartment volume and flow includes. Identify whether the list is exhaustive or includes a defined remainder.
2
Check volume coverage.
Sum mutually exclusive compartment volumes and compare with the declared whole-body volume. Investigate overlap, omitted tissues, or an incompatible body-volume convention before forcing the sum to match.
3
Reconcile systemic flow accounting.
Sum systemic destinations once and compare with cardiac output. Trace portal, shunt, and other routed flows to ensure a transfer within the circulation has not been counted as an additional cardiac delivery.
4
Inspect organ-level relationships.
Calculate \(Q_i/V_i\) and, when useful, \(Q_i/Q_{\mathrm{CO}}\). Compare with an appropriate reference using the same organ boundaries and flow definition.
5
Resolve discrepancies by tracing sources.
Check transcription, units, organ identity, and source definitions before modifying inputs. Any adjustment should preserve the constraints and have a physiological justification.

A common mistake is to regard a balanced sum as proof that the parameter set is plausible. The reasoning fails because summation can conceal compensating errors: one flow may be too low and another too high. The correction is to check both the totals and organ-specific flow-volume relationships. The converse mistake is to “fix” a sum by arbitrarily changing one organ. A numerical correction is not evidence of a correct physiological value.

Another failure mode is comparing values that use different boundaries—for example, a reported liver flow that includes portal inflow against a reference for hepatic arterial flow alone. A mismatch may then be definitional rather than physiological. Diagnostic checks should therefore record both the number and its meaning.

Choosing an Appropriate Comparison

Independent range checks are useful as an initial screen: they can quickly identify a negative volume, an implausible unit, or a flow exceeding the declared cardiac output. They do not enforce joint accounting. A constrained accounting audit adds the whole-body and cardiac-output equalities, while organ-specific comparisons test whether the allocation is credible. These approaches complement one another rather than compete.

When a set fails a joint equality, first check whether its components were defined consistently. If definitions are sound, the discrepancy may indicate missing compartments, incompatible data sources, or an incorrect input. A constrained fitting or reallocation can produce values that satisfy a sum, but it cannot determine which organ value is biologically correct without additional evidence. The audit identifies inconsistency; it does not automatically identify the true replacement value.

Key takeaway: Treat organ volumes and blood flows as a connected accounting system. Verify the compartment definitions, enforce whole-body volume and cardiac-output totals, and then evaluate organ-specific flow-volume relationships against appropriately matched physiological references.

Check Your Understanding

Answer each question, then compare your reasoning with the solutions below.

  1. A model lists nonoverlapping volumes of 1.2, 0.4, 20.0, and 28.4 L. Its declared body-volume target is 50.0 L. Does the volume balance hold?
  2. Systemic flows are 1.1, 0.8, and 2.6 L/min, and cardiac output is 4.5 L/min. What does the sum check show?
  3. Why should portal flow not be added to cardiac output a second time when it is already included in flow to the portal-drained tissues?
  4. An organ has a volume of 0.25 L and a flow of 0.75 L/min. Calculate its flow per unit volume and state what additional information is needed to judge plausibility.

Solutions. (1) The sum is \(1.2+0.4+20.0+28.4=50.0\) L, so the stated volume balance holds, assuming the compartments are exhaustive and nonoverlapping. (2) The flow sum is \(1.1+0.8+2.6=4.5\) L/min, matching cardiac output; this does not establish that each organ allocation is plausible. (3) Portal blood is transferred from the portal-drained tissues to the liver; it is not an additional independent delivery from the heart. Counting it at both stages double counts the same blood flow. (4) The ratio is \(0.75/0.25=3.00\) L/min/L. Judging it requires an organ-appropriate reference that matches the population, physiological state, and flow definition.