Tutorials › Physiologically-Based Pharmacokinetics (PBPK) › Why In Vitro Scaling Can Overpredict In Vivo Clearance

In Vitro to In Vivo Extrapolation of Metabolism · Tutorial 354 of 799

Why In Vitro Scaling Can Overpredict In Vivo Clearance

Learn to trace overpredicted in vitro-to-in vivo clearance estimates to assay activity, binding corrections, scaling inputs or duplicated adjustments.

Advanced 12 min read

What You'll Learn

  • Distinguish apparent intrinsic clearance from clearance corrected for incubation binding.
  • Identify how assay-specific enzyme activity can inflate a liver prediction.
  • Check units and biological relevance when selecting scaling factors.
  • Quantify how incorrect binding fractions affect predicted hepatic clearance.
  • Recognize duplicate corrections and scaling steps before interpreting a prediction.
  • Use a hepatic well-stirred calculation to show how intrinsic-clearance errors carry through to organ clearance.

Why a Scaled Prediction Can Be Too High

In vitro-to-in vivo extrapolation (IVIVE) converts a measured rate in a laboratory preparation into a predicted clearance for an organ or organism. The calculation can be arithmetically correct and still overpredict in vivo clearance: a laboratory activity may not represent activity in the target tissue, an adjustment may be inappropriate for the quantity measured, or a scaling operation may be applied more than once. The practical task is to trace each factor from the assay measurement to the final prediction and verify what it represents.

This tutorial focuses on four sources of overprediction: assay-specific activity treated as representative of in vivo activity, an incorrect incubation-binding correction, unsuitable biological scaling factors, and double counting. These are distinct problems. A large prediction alone does not identify which one occurred; the calculation and the provenance of each input must be examined.

Definition: Apparent intrinsic clearance, \(CL_{\mathrm{int,app}}\), is clearance estimated from an in vitro assay using the nominal substrate concentration. When the assay’s measured clearance is based on total substrate concentration and only unbound substrate is available for metabolism, the corresponding unbound intrinsic clearance is \(CL_{\mathrm{int,u}}=CL_{\mathrm{int,app}}/f_{\mathrm{u,inc}}\), where \(f_{\mathrm{u,inc}}\) is the unbound fraction in the incubation. This correction applies only when the input is apparent clearance on a total-concentration basis; it must not be repeated if the input is already unbound clearance.

For microsomal scaling, a clearance expressed per unit microsomal protein is multiplied by microsomal protein per gram of liver (MPPGL) and liver mass. The resulting whole-liver intrinsic clearance has units of volume per time. For a hepatocyte assay, the corresponding quantities are clearance per cell number, cells per gram of liver, and liver mass. Each factor must match the preparation, species, and units of the measured clearance.

Intrinsic clearance is not the same as hepatic clearance. Under the hepatic well-stirred model, hepatic clearance depends on intrinsic clearance, hepatic blood flow, and the unbound fraction in plasma. With \(Q_{\mathrm{h}}\) denoting hepatic blood flow and \(f_{\mathrm{u,p}}\) the unbound fraction in plasma, the model is:

$$ CL_{\mathrm{h}} = \frac{Q_{\mathrm{h}} f_{\mathrm{u,p}} CL_{\mathrm{int}}} {Q_{\mathrm{h}} + f_{\mathrm{u,p}} CL_{\mathrm{int}}} $$

The model assumes a well-mixed liver, linear intrinsic elimination over the concentration range considered, and consistent units for flow and clearance. It is useful for translating a scaled intrinsic clearance into an organ-clearance prediction, but it cannot repair an incorrect input.

How the Main Sources of Overprediction Arise

Assay-specific activity. An observed rate belongs to the preparation and conditions in which it was measured. A particular enzyme system may have greater activity per unit enzyme or preparation than the relevant activity in liver. Scaling that rate by an enzyme abundance or tissue quantity does not, by itself, make the activity representative of the target tissue. Any relative activity adjustment must be appropriate to the assay and target system. An excessive or inapplicable adjustment factor can therefore inflate the prediction.

Incorrect binding correction. Dividing apparent clearance by \(f_{\mathrm{u,inc}}\) increases the estimate when some substrate is bound in the incubation. If the measured clearance was already calculated on an unbound-concentration basis, dividing again inflates it. Even when correction is needed, the fraction must belong to the relevant incubation and conditions. A fraction from another preparation or an incorrectly entered value can produce a large error, especially when the fraction is small.

Unsuitable scaling factors. MPPGL, liver mass, and cell number per gram are biological quantities, not universal constants. A value from a different species, preparation, or population may not be suitable. Because these factors multiply the in vitro rate, using factors that are too large inflates the scaled clearance directly. Check both the source and the units of each factor before multiplying.

Double counting. Each adjustment should occur once, and only when required by the measurement. Examples include applying an incubation-binding correction to a clearance already expressed relative to unbound concentration, or applying tissue scaling to a result that already represents a whole-liver equivalent. Dimensional analysis can reveal some duplicated steps: the product of assay clearance per unit protein, MPPGL, and liver mass already has whole-liver clearance units. Multiplying by those tissue factors again has no valid dimensional interpretation.

A Short Justification: Why Intrinsic Clearance Errors Affect Organ Clearance

Under the well-stirred model, hepatic extraction is the fraction of drug removed from blood passing through the liver. The model gives \(E_{\mathrm{h}}=f_{\mathrm{u,p}}CL_{\mathrm{int}}/(Q_{\mathrm{h}}+f_{\mathrm{u,p}}CL_{\mathrm{int}})\), and hepatic clearance is flow multiplied by extraction: \(CL_{\mathrm{h}}=Q_{\mathrm{h}}E_{\mathrm{h}}\). Substitution yields the clearance equation above. This form also explains why a biased intrinsic clearance does not necessarily produce the same proportional bias in hepatic clearance: as \(f_{\mathrm{u,p}}CL_{\mathrm{int}}\) becomes large relative to \(Q_{\mathrm{h}}\), \(CL_{\mathrm{h}}\) approaches \(Q_{\mathrm{h}}\). The result is bounded by hepatic flow, although a prediction approaching that bound can still be based on a flawed input.

Worked Example: Using the Wrong Incubation Unbound Fraction

Suppose a microsomal clearance has been scaled to the whole liver and is \(CL_{\mathrm{int,app}}=0.60\ \mathrm{L/min}\). Assume the correct \(f_{\mathrm{u,inc}}\) is 0.50. For the hepatic calculation, use \(f_{\mathrm{u,p}}=0.050\) and \(Q_{\mathrm{h}}=1.50\ \mathrm{L/min}\). These are hypothetical values. Compare the prediction using the correct incubation fraction with one using an erroneous value of 0.167.

With the correct fraction, the scaled unbound intrinsic clearance is:

$$ CL_{\mathrm{int,u}} = \frac{0.60\ \mathrm{L/min}}{0.50} = 1.20\ \mathrm{L/min} $$

The unbound intrinsic term for the hepatic model is \(0.050 \times 1.20=0.0600\ \mathrm{L/min}\). Therefore:

$$ CL_{\mathrm{h}} = \frac{1.50 \times 0.0600}{1.50+0.0600} = 0.05769\ \mathrm{L/min} = 57.69\ \mathrm{mL/min} $$

Using the erroneous fraction gives \(0.60/0.167=3.5928\ldots\ \mathrm{L/min}\), or \(3.59\ \mathrm{L/min}\) to three significant figures. Retaining the unrounded quotient in the hepatic calculation:

$$ CL_{\mathrm{h}} = \frac{1.50 \times (0.050 \times 3.592814\ldots)} {1.50 + (0.050 \times 3.592814\ldots)} = 0.1604\ \mathrm{L/min} = 160.4\ \mathrm{mL/min} $$

The erroneous binding input raises predicted hepatic clearance from 57.69 to 160.4 mL/min. This difference follows from the incorrect fraction, not from a change in hepatic flow or plasma binding.

Worked Example: A Scaling Factor From the Wrong Basis

A hypothetical human hepatocyte assay reports \(8.00\ \mathrm{\mu L/min}\) per \(10^6\) cells. Suppose the suitable human scaling inputs are \(120 \times 10^6\) cells per gram of liver and a liver mass of \(1{,}500\ \mathrm{g}\). Compare those with an inappropriate set of inputs taken from a different basis: \(240 \times 10^6\) cells per gram and \(1{,}800\ \mathrm{g}\). For illustration, let \(f_{\mathrm{u,p}}=0.100\) and \(Q_{\mathrm{h}}=1.50\ \mathrm{L/min}\).

The suitable inputs imply \(120 \times 1{,}500=180{,}000\) million cells in the whole liver. Scaling gives:

$$ 8.00\ \frac{\mathrm{\mu L}}{\mathrm{min}\cdot 10^6\ \mathrm{cells}} \times 180{,}000 \times 10^6\ \mathrm{cells} = 1{,}440{,}000\ \mathrm{\mu L/min} = 1.44\ \mathrm{L/min} $$

For this example, treat the scaled result as \(CL_{\mathrm{int}}\). Then \(f_{\mathrm{u,p}}CL_{\mathrm{int}}=0.100 \times 1.44=0.144\ \mathrm{L/min}\), so the predicted hepatic clearance is:

$$ CL_{\mathrm{h}} = \frac{1.50 \times 0.144}{1.50+0.144} = 0.1314\ \mathrm{L/min} = 131.4\ \mathrm{mL/min} $$

The unsuitable inputs imply \(240 \times 1{,}800=432{,}000\) million cells and yield \(8.00 \times 432{,}000=3{,}456{,}000\ \mathrm{\mu L/min}=3.456\ \mathrm{L/min}\). The hepatic prediction then becomes:

$$ CL_{\mathrm{h}} = \frac{1.50 \times (0.100 \times 3.456)} {1.50 + (0.100 \times 3.456)} = \frac{0.5184}{1.8456} = 0.2809\ \mathrm{L/min} = 280.9\ \mathrm{mL/min} $$

The selected factors make the scaled intrinsic clearance 2.40 times larger and the modeled hepatic clearance about 2.14 times larger. The factors are not interchangeable merely because they produce the same units; their biological basis must fit the assay and the target.

Worked Example: Assay Activity That Is Not Representative of Liver

Suppose a hypothetical enzyme assay measures a rate equivalent to \(0.030\ \mathrm{\mu L/min}\) per pmol of enzyme. The amount of that enzyme used for scaling is estimated as \(100\ \mathrm{pmol/g}\) of liver, and liver mass is \(1{,}500\ \mathrm{g}\). Independently, assume the activity appropriate for the target liver system would be \(0.010\ \mathrm{\mu L/min}\) per pmol. Use \(f_{\mathrm{u,p}}=0.200\) and \(Q_{\mathrm{h}}=1.50\ \mathrm{L/min}\).

The scaled enzyme amount is \(100 \times 1{,}500=150{,}000\ \mathrm{pmol}\). Directly scaling the assay-specific activity gives:

$$ 0.030\ \frac{\mathrm{\mu L}}{\mathrm{min}\cdot\mathrm{pmol}} \times 150{,}000\ \mathrm{pmol} = 4{,}500\ \mathrm{\mu L/min} = 0.004500\ \mathrm{L/min} $$

Using the target-system activity instead gives \(0.010 \times 150{,}000=1{,}500\ \mathrm{\mu L/min}=0.001500\ \mathrm{L/min}\). For the assay-specific value, \(f_{\mathrm{u,p}}CL_{\mathrm{int}}=0.200 \times 0.004500=0.0009000\ \mathrm{L/min}\); the well-stirred prediction is:

$$ CL_{\mathrm{h}} = \frac{1.50 \times 0.0009000}{1.50+0.0009000} = 0.0008995\ \mathrm{L/min} = 0.8995\ \mathrm{mL/min} $$

With the target-system activity, \(f_{\mathrm{u,p}}CL_{\mathrm{int}}=0.0003000\ \mathrm{L/min}\), giving \(CL_{\mathrm{h}}=0.0003000\ \mathrm{L/min}=0.3000\ \mathrm{mL/min}\) to four significant figures. The threefold difference begins in the activity per pmol, before liver scaling. The example assumes that the stated target activity is appropriate; in an actual prediction, the evidence supporting that activity or any inter-system adjustment must be evaluated.

Diagnostics, Comparisons, and Limits

A useful review follows the calculation in the order the quantities enter it. First identify whether the assay result is apparent or already corrected for incubation binding. Next check that its denominator is clear: per milligram of microsomal protein, per number of hepatocytes, or per amount of enzyme. Then confirm that each scaling factor matches that denominator, the species, and the intended organ. Finally, verify whether the resulting intrinsic clearance is already scaled or binding-corrected before applying any further adjustment.

A dimensional audit is especially useful. For example, \(\mathrm{\mu L/min/mg}\) multiplied by \(\mathrm{mg/g}\) and \(\mathrm{g}\) gives \(\mathrm{\mu L/min}\), a whole-liver clearance. If a calculation requires multiplying that result by another \(\mathrm{mg/g}\) factor, the units no longer describe clearance. A factor should not be retained merely because a spreadsheet has a cell for it.

The main alternative to a direct scaled prediction is to report scaled intrinsic clearance without converting it to hepatic clearance, or to use a different in vitro system with its own appropriate scaling basis. These approaches answer different questions; neither makes an inappropriate activity or scaling factor valid. A comparison across preparations can help identify whether a result depends strongly on the chosen assay system, but interpretation still requires preparation-specific inputs.

The well-stirred model also has limitations: it represents the liver as a well-mixed organ and assumes linear intrinsic elimination for the calculation. A flow-limited ceiling can compress differences between large intrinsic-clearance estimates, so similar hepatic predictions do not prove that their underlying IVIVE calculations are sound. Conversely, a high predicted clearance is a reason to inspect inputs, not proof of a particular error. Other sources of IVIVE bias require their own evidence and should not be inferred solely from an overprediction.

Common Pitfall

Wrong reasoning: “The apparent clearance is low, so I should divide it by every unbound fraction or apply every available tissue factor to be conservative.” Each adjustment can seem individually plausible, but their cumulative use may correct the same feature twice or combine factors on incompatible bases.

Correction: State what each input measures, write its units, and apply a correction only if the input has not already incorporated it. The incubation fraction applies to apparent clearance measured against total incubation concentration; plasma binding enters the hepatic model separately. Keep those roles distinct, and use a tissue scaling factor only once for the relevant assay denominator.

Key takeaway: Overprediction can originate before, during, or after tissue scaling. Trace the assay activity, binding basis, scaling units, and any repeated adjustments separately; then carry the justified intrinsic clearance into the hepatic model.

Check Your Understanding

Answer each question, then compare your reasoning with the solutions.

  1. An apparent intrinsic clearance of \(0.40\ \mathrm{L/min}\) has \(f_{\mathrm{u,inc}}=0.40\). What is the unbound intrinsic clearance, and should it be divided by \(0.40\) again if the reported value is already unbound?
  2. A clearance of \(5.00\ \mathrm{\mu L/min}\) per \(10^6\) hepatocytes is scaled using \(100 \times 10^6\) cells/g and a liver mass of \(1{,}200\ \mathrm{g}\). What is the scaled whole-liver clearance?
  3. Why can a correct unit calculation still yield an overprediction if the assay activity per unit enzyme is not representative of liver?
  4. For \(CL_{\mathrm{int}}=2.00\ \mathrm{L/min}\), \(f_{\mathrm{u,p}}=0.050\), and \(Q_{\mathrm{h}}=1.00\ \mathrm{L/min}\), calculate \(CL_{\mathrm{h}}\).

Solutions. (1) \(0.40/0.40=1.00\ \mathrm{L/min}\). If the reported value is already unbound, do not divide again; the correction would be duplicated. (2) The total is \(100 \times 1{,}200=120{,}000\) million cells, so \(5.00 \times 120{,}000=600{,}000\ \mathrm{\mu L/min}=0.600\ \mathrm{L/min}\). (3) Scaling converts the measured activity to a tissue quantity; it does not establish that the measured activity matches the target system. An overlarge assay activity or inappropriate inter-system factor remains in the result. (4) \(f_{\mathrm{u,p}}CL_{\mathrm{int}}=0.050 \times 2.00=0.100\ \mathrm{L/min}\), so \(CL_{\mathrm{h}}=(1.00 \times 0.100)/(1.00+0.100)=0.09091\ \mathrm{L/min}=90.91\ \mathrm{mL/min}\).