Tutorials › Population Pharmacokinetics › Choosing Sampling Times for Patient-Level Precision

Therapeutic Drug Monitoring and Individual Predictions · Tutorial 536 of 599

Choosing Sampling Times for Patient-Level Precision

Compare candidate sampling schedules using parameter sensitivities and quantify how the resulting patient-level parameter uncertainty affects forecasts.

Advanced 12 min read

What You'll Learn

  • Calculate local concentration sensitivities to log clearance, volume, and absorption rate.
  • Compare candidate sampling times using an information matrix.
  • Propagate an approximate individual parameter covariance into forecast uncertainty.
  • Distinguish designs that identify parameters from designs that improve a particular forecast.
  • Recognize practical and model-based limits of sensitivity calculations.

Why Sampling Time Affects Patient-Level Precision

A concentration measurement is informative about a patient’s parameters only to the extent that the predicted concentration changes when those parameters change. That sensitivity depends on when the sample is collected. A late sample may help distinguish clearance values, while an early sample after an oral dose may be more responsive to absorption rate. A sample can also be precise analytically yet add little information about the forecast of interest.

The design question is therefore not simply “How many samples should be collected?” It is “At which times will the measurements most reduce uncertainty in the parameters or forecast that matter?” The answer depends on the dosing history, the model, residual error, the population-informed individual prior, and the target prediction. The calculations below are local: they describe sensitivity near a specified set of parameter values.

Definition: For a predicted concentration \(C(t;\theta)\), the local sensitivity to parameter \(\theta_j\) is the derivative of the prediction with respect to that parameter, evaluated at a specified parameter value. When parameters are represented on the log scale, the derivative \(\partial \log C(t;\theta)/\partial \log \theta_j\) describes the approximate proportional change in concentration for a proportional change in that parameter.

From Sensitivity to Information

Suppose the observed log concentrations \(y_i=\log C_i\) are described locally by a model \(f(t_i;\eta)=\log C(t_i;\eta)\), where \(\eta\) is a vector of transformed individual parameters. Assume that residual errors are independent, normally distributed, have mean zero, and share known variance \(\sigma^2\). Also assume the model and dosing times are correctly specified for this calculation. The sensitivity matrix \(J\) has one row per sample and one column per parameter:

$$ J_{ij}=\left.\frac{\partial f(t_i;\eta)}{\partial \eta_j}\right|_{\eta=\eta_0}. $$

Under the local linear approximation, the data contribute the information matrix \(J^\mathsf{T}J/\sigma^2\). If the individual’s prior distribution for \(\eta\) is approximately normal with covariance matrix \(\Omega\), its precision matrix is \(\Omega^{-1}\). The approximate posterior covariance is then

$$ \Sigma_{\text{post}}\approx \left(\Omega^{-1}+\frac{J^\mathsf{T}J}{\sigma^2}\right)^{-1}. $$

This expression assumes a locally adequate linearization, a correctly specified error model, and a positive-definite combined precision matrix. It is an approximation, not a replacement for fitting the full individual model. It makes the design principle explicit: sampling times matter through the rows of \(J\), while residual error and prior uncertainty determine how much those sensitivities can improve precision.

Worked Example: Clearance and Volume Sensitivity at Two Times

Worked Example: Clearance and Volume Sensitivity at Two Times

Consider a hypothetical one-compartment intravenous bolus model with \(C(t)=D V^{-1}\exp(-CLt/V)\), where \(CL\) is clearance and \(V\) is volume. Write \(k=CL/V\), and use log parameters \(\eta=(\log CL,\log V)\). Differentiating the log concentration gives

$$ \frac{\partial\log C}{\partial\log CL}=-kt,\qquad \frac{\partial\log C}{\partial\log V}=-1+kt. $$

For the hypothetical patient, take \(CL=5\) L/h and \(V=50\) L, so \(k=0.1\) h\(^{-1}\). Consider samples at \(t_1=0.103\) h and \(t_2=10.889\) h. The corresponding values of \(kt\) are 0.0103 and 1.0889. Thus

$$ J= \begin{pmatrix} -0.0103 & -0.9897\\ -1.0889 & 0.0889 \end{pmatrix}. $$

The early sample has strong local sensitivity to \(V\) and little sensitivity to \(CL\); the later sample has a different sensitivity pattern. With independent log-scale residual errors of variance \(\sigma^2=0.01\), the determinant of the data information matrix is

$$ \det\left(\frac{J^\mathsf{T}J}{\sigma^2}\right) =\frac{(\det J)^2}{(\sigma^2)^2} =\frac{\left[(-0.0103)(0.0889)-(-0.9897)(-1.0889)\right]^2}{(0.01)^2} =\frac{1.16337796}{0.0001} =1.163\times 10^4. $$

The determinant is a measure of joint information in these two log parameters under this local model and error assumption. The distinct sensitivity directions are important: two measurements that both respond almost identically to parameter changes can provide little ability to separate \(CL\) from \(V\), even if each measurement is individually precise. The determinant does not by itself state the uncertainty of every forecast, as the next example shows.

Turning Parameter Precision Into Forecast Precision

A useful design criterion is the uncertainty in a specified future prediction. If the future log concentration is \(g(\eta)=\log C(T;\eta)\), its sensitivity vector at the fitted or nominal parameter value is \(q=\nabla_\eta g\). A first-order Taylor approximation gives forecast variance due to parameter uncertainty as

$$ \operatorname{Var}\{g(\eta)\mid\text{data}\}\approx q^\mathsf{T}\Sigma_{\text{post}}q. $$

This is uncertainty in the predicted mean log concentration due to uncertainty in the individual parameters. It does not include future residual error or assay error. For a predictive distribution of a future observation, those sources would also need to be included under their appropriate model assumptions.

Worked Example: Comparing Uncertainty for Two Forecast Times

Continue with a hypothetical intravenous bolus case and log parameters \((\log CL,\log V)\). Suppose two sampling times have \(kt=0.2\) and \(kt=1\), so the sensitivity matrix is \(J=\begin{pmatrix}-0.2&-0.8\\-1&0\end{pmatrix}\). Assume independent log-scale residual errors with variance \(0.04\), and a normal individual prior with covariance \(\Omega=0.04I\), where \(I\) is the two-dimensional identity matrix. These are illustrative assumptions, not study estimates.

First calculate \(J^\mathsf{T}J=\begin{pmatrix}1.04&0.16\\0.16&0.64\end{pmatrix}\). The prior precision is \(25I\), and the data precision is \(J^\mathsf{T}J/0.04\). Therefore the posterior precision and covariance are

$$ \Omega^{-1}+\frac{J^\mathsf{T}J}{0.04} = \begin{pmatrix}51&4\\4&41\end{pmatrix}, \qquad \Sigma_{\text{post}} = \frac{1}{2075} \begin{pmatrix}41&-4\\-4&51\end{pmatrix}. $$

The determinant used in the inverse is \(51(41)-4(4)=2075\). For a forecast at \(kT=0.5\), the sensitivity vector is \(q=(-0.5,-0.5)^\mathsf{T}\). Its approximate log-concentration variance is

$$ q^\mathsf{T}\Sigma_{\text{post}}q =\frac{0.25(41)+2(0.25)(-4)+0.25(51)}{2075} =\frac{21}{2075} =0.01012. $$

The corresponding standard deviation is \(\sqrt{0.01012}=0.1006\) log-concentration units. At a different forecast time, \(kT=1.5\), \(q=(-1.5,0.5)^\mathsf{T}\), and

$$ q^\mathsf{T}\Sigma_{\text{post}}q =\frac{2.25(41)+0.25(51)+2(-1.5)(0.5)(-4)}{2075} =\frac{111}{2075} =0.05349. $$

The standard deviation is \(\sqrt{0.05349}=0.2313\) log-concentration units. Under these assumptions, the forecast at \(kT=0.5\) is more precise than the forecast at \(kT=1.5\). This comparison is about parameter uncertainty in the two specified forecasts; it is not a universal ranking of those sampling times for every target.

Absorption-Phase Samples and Parameter Sensitivity

For first-order oral absorption in a one-compartment model, ignoring factors constant with respect to time and \(k_a\), the concentration is proportional to

$$ \frac{k_a}{k_a-k}\left(e^{-kt}-e^{-k_a t}\right), $$

where \(k_a\) is the absorption rate constant. An early sample can be sensitive to \(k_a\), while a sample after absorption is largely complete may carry little local information about it. This does not mean that an early measurement uniquely identifies absorption: parameter sensitivities can point in similar directions, and other parameters also affect the concentration.

Worked Example: A Sample’s Sensitivity to Absorption Rate

Take a hypothetical oral dose with \(k=0.1\) h\(^{-1}\), \(k_a=1\) h\(^{-1}\), and evaluate the concentration at \(t=0.25\) h. For the concentration factor above, the log sensitivity to \(k_a\) is

$$ \frac{\partial\log C}{\partial\log k_a} =-\frac{k}{k_a-k} +\frac{k_a t e^{-k_a t}}{e^{-kt}-e^{-k_a t}}. $$

Substitution gives

$$ -\frac{0.1}{1-0.1} +\frac{(1)(0.25)e^{-0.25}}{e^{-0.025}-e^{-0.25}} =-0.1111+\frac{0.1947}{0.1965} \approx 0.880. $$

Locally, a 1% increase in \(k_a\) corresponds to about a 0.88% increase in concentration at this time, holding the other parameters fixed. At \(t=4\) h, the same calculation gives

$$ -\frac{0.1}{0.9} +\frac{(1)(4)e^{-4}}{e^{-0.4}-e^{-4}} =-0.1111+\frac{0.07326}{0.6520} \approx 0.0013. $$

At this later time, the local concentration is nearly insensitive to \(k_a\) at the chosen parameter values. The comparison supports sampling during the absorption phase when absorption parameters matter, but it does not establish that one early sample is sufficient to estimate them.

Choosing a Design Criterion and Checking Its Limits

Several criteria can compare candidate schedules, and they answer different questions. A determinant criterion, such as the determinant of the information matrix, rewards joint information across parameters and is often interpreted through the local volume of the parameter uncertainty region. A criterion based on the trace of the covariance matrix summarizes overall parameter variance, but depends on parameter scaling. For a clinical forecast, directly comparing \(q^\mathsf{T}\Sigma_{\text{post}}q\) for the target times or outcomes is often more relevant. These criteria can rank the same candidate schedules differently.

A practical comparison should also account for feasibility: sample timing relative to doses, clinic attendance, assay limits, and whether a proposed time is tolerable for the patient. A theoretically informative time may not be usable. Model structure matters as well: if the absorption model, dose history, or residual-error assumptions are wrong, calculated precision can be misleading. Sensitivity-based designs are local, so a design optimized at one nominal parameter value may perform differently for a patient with substantially different parameters.

Diagnostics include checking whether sensitivity columns are nearly proportional, whether the information matrix is ill-conditioned, and whether small changes in nominal parameters or sample times greatly change the ranking. Such patterns indicate that parameters may remain difficult to distinguish or that the local result is fragile. Compare candidate schedules across plausible individual parameter values and inspect the forecast variance for the actual prediction target. The earlier material on parameter correlation in individual Bayesian fits is relevant here: strong posterior correlation can remain even when marginal standard errors appear moderate.

Common pitfall: “The highest concentration is the most informative sample, so sampling at the peak must give the most precise patient forecast.” This reasoning confuses concentration magnitude with parameter sensitivity. Information depends on how the predicted value changes with each parameter relative to residual error, and forecast precision depends on how parameter uncertainty projects onto the target forecast. Compare sensitivities and the resulting target-specific uncertainty instead.

No single time is best for every parameter and every forecast. In the intravenous example, early and late samples supplied different directions of information about clearance and volume. In the oral example, an early absorption-phase sample was more sensitive to \(k_a\) than a late sample. In practice, candidate times should be evaluated jointly with the individual prior, measurement-error model, plausible parameter range, and intended prediction. The resulting calculation guides design; it does not guarantee precise predictions if the model or assumptions fail.

Check Your Understanding

Answer each question, then compare your reasoning with the solutions.

  1. In the intravenous bolus model, what are the local log-concentration sensitivities to log clearance and log volume?
  2. Why can two precise measurements provide weak joint information about two parameters?
  3. For the second worked example, what is the approximate log-concentration standard deviation for the forecast at \(kT=1.5\)?
  4. Why does a sample with a large concentration not necessarily provide the most precise patient-specific forecast?

Solutions. (1) The sensitivities are \(-kt\) for log clearance and \(-1+kt\) for log volume. (2) If the measurements respond to parameter changes in nearly the same direction, the sensitivity matrix has nearly dependent columns and the parameters are difficult to distinguish. (3) The variance is \(111/2075=0.05349\), so the standard deviation is \(\sqrt{0.05349}=0.2313\) log-concentration units. (4) Concentration magnitude alone does not determine sensitivity relative to residual error or how parameter uncertainty affects the forecast target.

Clinical Biostats